Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.5194/hess-28-1999-2024 |
Evaluation of reanalysis soil moisture products using cosmic ray neutron sensor observations across the globe | |
Zheng, Yanchen; Coxon, Gemma; Woods, Ross; Power, Daniel; Rico-Ramirez, Miguel Angel; McJannet, David; Rosolem, Rafael; Li, Jianzhu; Feng, Ping | |
通讯作者 | Zheng, YC |
来源期刊 | HYDROLOGY AND EARTH SYSTEM SCIENCES
![]() |
ISSN | 1027-5606 |
EISSN | 1607-7938 |
出版年 | 2024 |
卷号 | 28期号:9页码:1999-2022 |
英文摘要 | Reanalysis soil moisture products are valuable for diverse applications, but their quality assessment is limited due to scale discrepancies when compared to traditional in situ point-scale measurements. The emergence of cosmic ray neutron sensors (CRNSs) with field-scale soil moisture estimates ( similar to 250 m radius, up to 0.7 m deep) is more suitable for the product evaluation owing to their larger footprint. In this study, we perform a comprehensive evaluation of eight widely used reanalysis soil moisture products (ERA5-Land, CFSv2, MERRA2, JRA55, GLDAS-Noah, CRA40, GLEAM and SMAP L4 datasets) against 135 CRNS sites from the COSMOS-UK, COSMOS-Europe, COSMOS USA and CosmOz Australia networks. We evaluate the products using six metrics capturing different aspects of soil moisture dynamics. Results show that all reanalysis products generally exhibit good temporal correlation with the measurements, with the median temporal correlation coefficient ( R ) values spanning 0.69 to 0.79, though large deviations are found at sites with seasonally varying vegetation cover. Poor performance is observed across products for soil moisture anomalies time series, with R values varying from 0.46 to 0.66. The performance of reanalysis products differs greatly across regions, climate, land covers and topographic conditions. In general, all products tend to overestimate data in arid climates and underestimate data in humid regions as well as grassland. Most reanalysis products perform poorly in steep terrain. Relatively low temporal correlation and high bias are detected in some sites from the west of the UK, which might be associated with relatively low bulk density and high soil organic carbon. Overall, ERA5-Land, CRA40, CFSv2, SMAP L4 and GLEAM exhibit superior performance compared to MERRA2, GLDAS-Noah and JRA55. We recommend that ERA5-Land and CFSv2 could be used in humid climates, whereas SMAP L4 and CRA40 perform better in arid regions. SMAP L4 has good performance for cropland, while GLEAM is more effective in shrubland regions. Our findings also provide insights into directions for improvement of soil moisture products for product developers. |
类型 | Article |
语种 | 英语 |
开放获取类型 | gold, Green Submitted |
收录类别 | SCI-E |
WOS记录号 | WOS:001214907900001 |
WOS关键词 | IN-SITU ; WATER CONTENT ; SCALE EVALUATION ; 22 PRECIPITATION ; SATELLITE ; SURFACE ; ASSIMILATION ; CALIBRATION ; SYSTEM ; SMOS |
WOS类目 | Geosciences, Multidisciplinary ; Water Resources |
WOS研究方向 | Geology ; Water Resources |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/404128 |
推荐引用方式 GB/T 7714 | Zheng, Yanchen,Coxon, Gemma,Woods, Ross,et al. Evaluation of reanalysis soil moisture products using cosmic ray neutron sensor observations across the globe[J],2024,28(9):1999-2022. |
APA | Zheng, Yanchen.,Coxon, Gemma.,Woods, Ross.,Power, Daniel.,Rico-Ramirez, Miguel Angel.,...&Feng, Ping.(2024).Evaluation of reanalysis soil moisture products using cosmic ray neutron sensor observations across the globe.HYDROLOGY AND EARTH SYSTEM SCIENCES,28(9),1999-2022. |
MLA | Zheng, Yanchen,et al."Evaluation of reanalysis soil moisture products using cosmic ray neutron sensor observations across the globe".HYDROLOGY AND EARTH SYSTEM SCIENCES 28.9(2024):1999-2022. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。