英文摘要The earth -to -air heat exchanger (EAHE) is a remarkable technology that taps into the Earth's subsurface heat to either heat or cool the air circulating within buried underground pipes, which can effectively reduce building energy consumption. In cold -arid regions of northwest China, outdoor climate parameters vary considerably throughout the year, and shallow soil temperatures also fluctuate dramatically. This dynamic thermal environment significantly impacts the practical application of the EAHE system. Furthermore, the operation efficiency of the EAHE system can be influenced by the configuration of system parameters. Therefore, this paper takes an EAHE project in Lanzhou as the research object to investigate the operation performance, energy consumption and economy of EAHE in the cold -arid regions of Northwest China. The research results show that heat exchange potential is high in summer and winter, and the outlet temperature varies more gently in winter. During the summer, the cooling capacity of the system is sufficient to the cooling demands of the building, without using auxiliary equipment for cooling; compared to an air-cooled unit with a COP of 3.2, the system reduces cooling energy consumption by 2063.4 kWh. Moreover, we determined the influence degree and optimal scheme of each factor under different evaluation indexes through orthogonal simulation. The specific parameters of the optimal scheme are as follows: pipe length 20 m, pipe diameter 100 mm, buried depth 4 m, and airflow velocity 7 m/s. Compared with the original scheme, the heat transfer efficiency and heat transfer power of this scheme are increased by 37.91 % and 17.6 %, respectively, and the cost per unit heat transfer power is 11,700 CNY/kW, which is 8000 CNY/kW lower than the original scheme.
英文关键词Earth-to-air heat exchanger Cold-arid climate Orthogonal simulation Configuration optimization
类型Article
语种英语
收录类别SCI-E
WOS记录号WOS:001200045600001
WOS关键词THERMAL PERFORMANCE ; HYBRID EARTH ; PREDICTION ; ENERGY ; MODEL
WOS类目Construction & Building Technology ; Energy & Fuels ; Engineering, Civil
WOS研究方向Construction & Building Technology ; Energy & Fuels ; Engineering
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/403490
推荐引用方式
GB/T 7714
Zhang, Dong,Zhang, Jingrui,Liu, Chunyang,et al. Performance measurement and configuration optimization based on orthogonal simulation method of earth-to-air heat exchange system in cold-arid climate[J],2024,308.
APA Zhang, Dong,Zhang, Jingrui,Liu, Chunyang,Yan, Chengtao,Ji, Jinchao,&An, Zhoujian.(2024).Performance measurement and configuration optimization based on orthogonal simulation method of earth-to-air heat exchange system in cold-arid climate.ENERGY AND BUILDINGS,308.
MLA Zhang, Dong,et al."Performance measurement and configuration optimization based on orthogonal simulation method of earth-to-air heat exchange system in cold-arid climate".ENERGY AND BUILDINGS 308(2024).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Dong]的文章
[Zhang, Jingrui]的文章
[Liu, Chunyang]的文章
百度学术
百度学术中相似的文章
[Zhang, Dong]的文章
[Zhang, Jingrui]的文章
[Liu, Chunyang]的文章
必应学术
必应学术中相似的文章
[Zhang, Dong]的文章
[Zhang, Jingrui]的文章
[Liu, Chunyang]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。