Evaluating Viscosity and Tear Breakup Time of Contemporary Commercial Ocular Lubricants on an In Vitro Eye Model
Phan, Chau-Minh; Ross, Mitchell; Fahmy, Karim; McEwen, Blair; Hofmann, Ilan; Chan, Vivian W. Y.; Clark-Baba, Connor; Jones, Lyndon
通讯作者Phan, CM
来源期刊TRANSLATIONAL VISION SCIENCE & TECHNOLOGY
ISSN2164-2591
出版年2023
卷号12期号:6
英文摘要Purpose: To evaluate the link between the viscosity of ophthalmic formulation and tear film stability using a novel in vitro eye model.Methods: The viscosities and noninvasive tear breakup time (NIKBUT) of 13 commercial ocular lubricants were measured to evaluate the correlation between viscosity and NIKBUT. The complex viscosity of each lubricant was measured three times for each angular frequency (ranging from 0.1 to 100 rad/s) using the Discovery HR-2 hybrid rheometer. The NIKBUT measurements were performed eight times for each lubricant using an advanced eye model mounted on the OCULUS Keratograph 5M. A contact lens (CL; ACUVUE OASYS [etafilcon A]) or a collagen shield (CS) was used as the simulated corneal surface. Phosphate-buffered saline was used as a simulated fluid.Results: The results showed a positive correlation between viscosity and NIKBUT at high shear rates (at 10 rad/s, r = 0.67) but not at low shear. This correlation was even better for viscosities between 0 and 100 mPa*s (r = 0.85). Most of the lubricants tested in this study also had shear-thinning properties. OPTASE INTENSE, I-DROP PUR GEL, I DROP MGD, OASIS TEARS PLUS, and I-DROP PUR had higher viscosity in comparison to other lubricants (P < 0.05). All of the formulations had a higher NIKBUT than the control (2.7 +/- 1.2 seconds for CS and 5.4 +/- 0.9 seconds for CL) without any lubricant (P < 0.05). I-DROP PUR GEL, OASIS TEARS PLUS, I-DROP MGD, REFRESH OPTIVE ADVANCED, and OPTASE INTENSE had the highest NIKBUT using this eye model.Conclusions: The results show that the viscosity is correlated with NIKBUT, but further work is necessary to determine the underlying mechanisms.Translational Relevance: The viscosity of ocular lubricants can affect NIKBUT and tear film stability, so it is an important property to consider when formulating ocular lubricants.
英文关键词viscosity ocular lubricants in vitro eye model tear breakup
类型Article
语种英语
开放获取类型gold, Green Published
收录类别SCI-E
WOS记录号WOS:001108907400003
WOS关键词UP TIME ; FILM ; FORMULATIONS ; DISEASE ; SYSTEMS
WOS类目Ophthalmology
WOS研究方向Ophthalmology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/398919
推荐引用方式
GB/T 7714
Phan, Chau-Minh,Ross, Mitchell,Fahmy, Karim,et al. Evaluating Viscosity and Tear Breakup Time of Contemporary Commercial Ocular Lubricants on an In Vitro Eye Model[J],2023,12(6).
APA Phan, Chau-Minh.,Ross, Mitchell.,Fahmy, Karim.,McEwen, Blair.,Hofmann, Ilan.,...&Jones, Lyndon.(2023).Evaluating Viscosity and Tear Breakup Time of Contemporary Commercial Ocular Lubricants on an In Vitro Eye Model.TRANSLATIONAL VISION SCIENCE & TECHNOLOGY,12(6).
MLA Phan, Chau-Minh,et al."Evaluating Viscosity and Tear Breakup Time of Contemporary Commercial Ocular Lubricants on an In Vitro Eye Model".TRANSLATIONAL VISION SCIENCE & TECHNOLOGY 12.6(2023).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Phan, Chau-Minh]的文章
[Ross, Mitchell]的文章
[Fahmy, Karim]的文章
百度学术
百度学术中相似的文章
[Phan, Chau-Minh]的文章
[Ross, Mitchell]的文章
[Fahmy, Karim]的文章
必应学术
必应学术中相似的文章
[Phan, Chau-Minh]的文章
[Ross, Mitchell]的文章
[Fahmy, Karim]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。