DOI | 10.1016/j.jchromb.2022.123564 |
Optimization and validation of the liquid chromatography coupled to tandem mass spectrometry method for assessing octreotide release from microspheres during inflammation in rabbit models | |
Wang, Gaoyu; Liu, Xinghua; Huo, Qiurui; Lin, Shilan; Wang, Wenyan; Liu, Chunjiao; Sha, Chunjie; Liu, Wanhui | |
通讯作者 | Wang, WY |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2023 |
卷号 | 1214 |
英文摘要 | To study the effect of acute-phase reaction (APR) of inflammation on the release of octreotide acetate micro -sphere (Sandostatin (R), SLAR) at a clinical dose, a more sensitive liquid chromatography coupled to tandem mass spectrometry analysis method needs to be developed because of the low plasma concentrations of octreotide. Solid-phase microextraction with an Oasis (R) HLB mu Elution plate was adopted for sample preparation. Extraction recovery ranged from 65.7 % to 73.2 %, and the matrix effect was negligible. High sensitivity and an intense chromatographic peak were acquired by optimizing the chromatography and mass spectrometry conditions. The lower limit of quantitation (LLOQ) was 0.01 ng/mL based on 100 mu L of plasma, and linearity ranged from 0.01 to 5.0 ng/mL. The coefficients of variations for intraday and interday precision were less than 4.4 %, and the relative error of accuracy was within 5.7 %. The validated method was successfully applied to pharmacokinetics studies of SLAR in a seven-day inflammation model of rabbits, indicating that the APR did not affected the release and pharmacokinetics of the octreotide microspheres. |
英文关键词 | Octreotide Microsphere Rabbit inflammation models HLB ?Elution Pharmacokinetics |
类型 | Article |
语种 | 英语 |
开放获取类型 | Bronze |
收录类别 | SCI-E |
WOS记录号 | WOS:000914601800005 |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/397210 |
推荐引用方式 GB/T 7714 | Wang, Gaoyu,Liu, Xinghua,Huo, Qiurui,et al. Optimization and validation of the liquid chromatography coupled to tandem mass spectrometry method for assessing octreotide release from microspheres during inflammation in rabbit models[J],2023,1214. |
APA | Wang, Gaoyu.,Liu, Xinghua.,Huo, Qiurui.,Lin, Shilan.,Wang, Wenyan.,...&Liu, Wanhui.(2023).Optimization and validation of the liquid chromatography coupled to tandem mass spectrometry method for assessing octreotide release from microspheres during inflammation in rabbit models.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,1214. |
MLA | Wang, Gaoyu,et al."Optimization and validation of the liquid chromatography coupled to tandem mass spectrometry method for assessing octreotide release from microspheres during inflammation in rabbit models".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 1214(2023). |