英文摘要This work highlights the methodology for the development of diffusive gradients in thin films (o-DGT) through its adaptation for 12 natural and synthetic hormones belonging to three different families (estrogens, progestins, and androgens). A reliable strategy must be applied during o-DGT lab adaptation to avoid issues related to the analysis (i.e., presence of matrix effects in grab or passive samples) but also to the o-DGT configuration (i.e., undesirable sorption or desorption, lack of performance with insufficient elution or unreliable diffusion coefficient). To avoid analytical issues due to the presence of salts in grab samples, CaCl2 exposure solutions must be used on a lab-scale development to monitor the hormone concentration. The selected o-DGT was composed of an Oasis (R) HLB binding gel and a diffusive gel in agarose because they provided better performance than polyacrylamide gels (i.e., higher elution factors and more repeatable diffusion coefficients). The elution factors of the binding gel were then from 0.79 +/- 0.13 to 1.04 +/- 0.13 (RSD < 15%) and the diffusion coefficients at 25 degrees C were from 4.07 +/- 0.24 to 5.49 +/- 0.28 x 10(-6) cm(2) s(-1) (RSD < 9%). A laboratory exposure to a synthetic solution was performed to check the consistency with the DGT quantification model validating the calibration parameters for all hormones (except 17 alpha-ethinylestradiol with a bias of 40%). Therefore, the o-DGT configuration is suitable for sampling hormones in the natural environment with LOQ(DGT) ranging from 0.3 to 6.6 ng L-1.
英文关键词Hormones Passive sampling o-DGT Diffusion coefficients Water monitoring LC-MS MS analysis
类型Article
语种英语
收录类别SCI-E
WOS记录号WOS:000983703400013
WOS关键词ENDOCRINE DISRUPTING CHEMICALS ; THIN-FILMS TECHNIQUE ; DIFFUSIVE GRADIENTS ; SURFACE-WATER ; ESTROGENS ; SAMPLERS
WOS类目Environmental Sciences
WOS研究方向Environmental Sciences & Ecology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/396270
推荐引用方式
GB/T 7714
Martins de Barros, Rachel,Lissalde, Sophie,Guibal, Robin,et al. Adaptation of the o-DGT for the sampling of 12 hormones: calibration, performance evaluation, and recommendation[J],2023,30(26):68177-68190.
APA Martins de Barros, Rachel,Lissalde, Sophie,Guibal, Robin,&Guibaud, Gilles.(2023).Adaptation of the o-DGT for the sampling of 12 hormones: calibration, performance evaluation, and recommendation.ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH,30(26),68177-68190.
MLA Martins de Barros, Rachel,et al."Adaptation of the o-DGT for the sampling of 12 hormones: calibration, performance evaluation, and recommendation".ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH 30.26(2023):68177-68190.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Martins de Barros, Rachel]的文章
[Lissalde, Sophie]的文章
[Guibal, Robin]的文章
百度学术
百度学术中相似的文章
[Martins de Barros, Rachel]的文章
[Lissalde, Sophie]的文章
[Guibal, Robin]的文章
必应学术
必应学术中相似的文章
[Martins de Barros, Rachel]的文章
[Lissalde, Sophie]的文章
[Guibal, Robin]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。