Evaluation of direct coupling between conventional windmills and reverse osmosis desalination systems at low wind speeds | |
Okura, Shiyoji S.; Ponte, Mateus C. A.; Palombella, Fabian O.; da Silva, Luan S.; Dias, Samuel V.; Almeida, Joao R. F.; Matos, Francisco F. S. | |
通讯作者 | Matos, FFS |
来源期刊 | ENERGY CONVERSION AND MANAGEMENT
![]() |
ISSN | 0196-8904 |
EISSN | 1879-2227 |
出版年 | 2023 |
卷号 | 295 |
英文摘要 | Installing windmills in dispersed communities with scarce water resources and a limited conventional electricity grid, such as the semi-arid regions of northeast Brazil with a low human development index, visibly improves people's quality of life. The situation becomes even more challenging when the artesian wells, from which windmills draw water, contain brackish water, as more energy must be employed for desalination. Reverse osmosis (RO) desalination systems have been employed worldwide and are todays most common. However, RO membrane systems can only withstand mild pressure variations, which can limit their direct use with conven-tional windmills since windmills' reciprocating pumps produce abrupt pressure variations. In this context, the present work aims to experimentally quantify the pressure gradients caused by piston pumps driven by windmills and confirm whether they can be used in conjunction with RO systems. To this end, an experimental apparatus was constructed, comprising a geared motor with a frequency inverter to simulate the windmill, a piston pump, and a conventional RO system. As a potential solution to mitigate abrupt pressure variations, a hydraulic pressure accumulator was utilized. As anticipated, high-pressure gradients were observed that exceeded the limits supported by the membranes during testing of the reference case (without a pressure accumulator). By employing the pressure accumulator, a reduction of 68.1% in pressure gradients was observed for the tested wind speeds, thereby enabling the direct coupling of windmills to RO systems in low wind speed conditions. |
英文关键词 | Windmill Piston pump Reverse osmosis Pressure gradient |
类型 | Article |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:001145799900001 |
WOS关键词 | WATER ; ENERGY |
WOS类目 | Thermodynamics ; Energy & Fuels ; Mechanics |
WOS研究方向 | Thermodynamics ; Energy & Fuels ; Mechanics |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/396069 |
推荐引用方式 GB/T 7714 | Okura, Shiyoji S.,Ponte, Mateus C. A.,Palombella, Fabian O.,et al. Evaluation of direct coupling between conventional windmills and reverse osmosis desalination systems at low wind speeds[J],2023,295. |
APA | Okura, Shiyoji S..,Ponte, Mateus C. A..,Palombella, Fabian O..,da Silva, Luan S..,Dias, Samuel V..,...&Matos, Francisco F. S..(2023).Evaluation of direct coupling between conventional windmills and reverse osmosis desalination systems at low wind speeds.ENERGY CONVERSION AND MANAGEMENT,295. |
MLA | Okura, Shiyoji S.,et al."Evaluation of direct coupling between conventional windmills and reverse osmosis desalination systems at low wind speeds".ENERGY CONVERSION AND MANAGEMENT 295(2023). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。