Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.2478/acph-2023-0041 |
Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis | |
Pavlovic, Dragana Mutavdzic; Babic, Sandra; Cizmic, Mirta; Sertic, Miranda; Pinusic, Tea | |
通讯作者 | Pavlovic, DM |
来源期刊 | ACTA PHARMACEUTICA
![]() |
ISSN | 1330-0075 |
EISSN | 1846-9558 |
出版年 | 2023 |
卷号 | 73期号:4页码:515-535 |
英文摘要 | Solid-phase extraction (SPE) coupled with capillary electrophoresis (CE) for the determination of macrolide antibiotics (azithromycin, clarithromycin, roxithromycin, tylosin) and tiamulin in water samples was described in this article. These compounds were extracted with different types of sorbents ( Oasis HLB, C18, C8, SDB, and Strata-X) and different masses of sorbents (60 mg, 200 mg, and 500 mg) using different organic solvents (methanol, ethanol, and acetonitrile) and different pH values of water samples (pH 7.00, 8.00, and 9.00). It was found that the highest extraction efficiency of the studied compounds was obtained with 200 mg/3 mL C18 cartridges with methanol as eluent at pH 9.00 of the water sample. The developed SPE-CE method for macrolide antibiotics and tiamulin was validated for linearity, precision, repeatability, the limit of detection (LOD), the limit of quantification (LOQ), and recovery. Good linearity was obtained in the range of 0.3-30 mg L-1 depending on the drug, with correlation coefficients higher than 0.9958 in all cases except clarithromycin (0.9873). Expanded measurement uncertainties were calculated for each pharmaceutical, accounting for 20.31 % (azithromycin), 38.33 % (tiamulin), 28.95 % (clarithromycin), 26.99 % (roxithromycin), and 21.09 % (tiamulin). Uncertainties associated with precision and calibration curves contributed the most to the combined measurement uncertainty. The method was successfully applied to the analysis of production waste-water from the pharmaceutical industry. |
英文关键词 | macrolides tiamulin solid-phase extraction capillary electrophoresis wastewater measurement uncertainty |
类型 | Article |
语种 | 英语 |
开放获取类型 | Green Published, gold |
收录类别 | SCI-E |
WOS记录号 | WOS:001133120100002 |
WOS关键词 | PERFORMANCE LIQUID-CHROMATOGRAPHY ; TANDEM MASS-SPECTROMETRY ; URBAN WASTE-WATER ; PHARMACEUTICALS ; ANTIBIOTICS ; ERYTHROMYCIN ; ENVIRONMENT ; RESIDUES ; FATE ; FOOD |
WOS类目 | Pharmacology & Pharmacy |
WOS研究方向 | Pharmacology & Pharmacy |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/394965 |
推荐引用方式 GB/T 7714 | Pavlovic, Dragana Mutavdzic,Babic, Sandra,Cizmic, Mirta,et al. Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis[J],2023,73(4):515-535. |
APA | Pavlovic, Dragana Mutavdzic,Babic, Sandra,Cizmic, Mirta,Sertic, Miranda,&Pinusic, Tea.(2023).Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis.ACTA PHARMACEUTICA,73(4),515-535. |
MLA | Pavlovic, Dragana Mutavdzic,et al."Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis".ACTA PHARMACEUTICA 73.4(2023):515-535. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。