Study on the Influencing Factors of Energy Consumption of Nearly Zero Energy Residential Buildings in Cold and Arid Regions of Northwest China
Yang, Jieyuan; Yuan, Hao; Yang, Jingbo; Zhu, Ruilin
通讯作者Yang, JY
来源期刊SUSTAINABILITY
EISSN2071-1050
出版年2022
卷号14期号:23
英文摘要There are many factors influencing the energy consumption of buildings in complex working conditions. In order to study the factors influencing the energy consumption of residential buildings with nearly zero energy in cold and arid regions of northwest China, factors such as the roof heat transfer coefficient (K-R), exterior wall heat transfer coefficient (K-E), ground heat transfer coefficient (K-G), exterior window heat transfer coefficient (K-EW), north window wall ratio (WWRN), south window wall ratio (WWRS), east west window wall ratio (WWRWE), building orientation (BO), and ventilation times (VT) are taken as the influencing factors in this paper. Using the orthogonal test, 135 building energy consumption calculation models were built in DeST, and the influence of 9 factors on building energy consumption in 5 types of regions (severe cold region A (1A), severe cold region B (1B), severe cold region C (1C), cold region A (2A), and cold region B (2B)) were analyzed. The conclusions are as follows: in the process of realizing nearly zero energy of residential buildings in the cold and arid regions of northwest China, the K-R, K-E, K-G, K-EW, WWRN, WWEWE should be reduced as much as possible in the five regions. The 1A,1B,1C regions should increase WWEWE and VT, with BO of about 15 degrees east of due north and VT of about 5, 8, and 10 times per hour, respectively. The WWES, BO and VT for the 2A region should be set at round 0.45, north-south, and about 10 times per hour, respectively. For the 2B region, WWES should be set at around 0.45, BO around 15 degrees east of due north, and VT as low as possible within the scope of the 'technical standard for nearly zero energy buildings'.
英文关键词nearly zero energy building building energy consumption orthogonal test multifactorial influence
类型Article
语种英语
开放获取类型gold
收录类别SCI-E ; SSCI
WOS记录号WOS:000897430500001
WOS关键词OPTIMIZATION
WOS类目Green & Sustainable Science & Technology ; Environmental Sciences ; Environmental Studies
WOS研究方向Science & Technology - Other Topics ; Environmental Sciences & Ecology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/394686
推荐引用方式
GB/T 7714
Yang, Jieyuan,Yuan, Hao,Yang, Jingbo,et al. Study on the Influencing Factors of Energy Consumption of Nearly Zero Energy Residential Buildings in Cold and Arid Regions of Northwest China[J],2022,14(23).
APA Yang, Jieyuan,Yuan, Hao,Yang, Jingbo,&Zhu, Ruilin.(2022).Study on the Influencing Factors of Energy Consumption of Nearly Zero Energy Residential Buildings in Cold and Arid Regions of Northwest China.SUSTAINABILITY,14(23).
MLA Yang, Jieyuan,et al."Study on the Influencing Factors of Energy Consumption of Nearly Zero Energy Residential Buildings in Cold and Arid Regions of Northwest China".SUSTAINABILITY 14.23(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yang, Jieyuan]的文章
[Yuan, Hao]的文章
[Yang, Jingbo]的文章
百度学术
百度学术中相似的文章
[Yang, Jieyuan]的文章
[Yuan, Hao]的文章
[Yang, Jingbo]的文章
必应学术
必应学术中相似的文章
[Yang, Jieyuan]的文章
[Yuan, Hao]的文章
[Yang, Jingbo]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。