英文摘要Amniocentesis involves taking a sample of the amniotic fluid in order to perform a karyotype test and diagnose any genetic defects that may affect the fetus. Amniotic fluid has been collected from patients with an indication for amniocentesis in the 15-26th week of pregnancy. A simple and sensitive high-performance liquid chromatography with fluorescence detection (HPLC-FLD) method for identification and quantification of eleven selected bisphenols in amniotic fluid samples is proposed. The proposed method involved protein precipitation using acetonitrile, and next the extraction and concentration of analytes by solid-phase extraction (SPE). The solid-phase extraction (SPE) procedure with application of Oasis HLB SPE columns performed well for the majority of the analytes, with recoveries in the range of 67-121% and relative standard deviations (RSD%) less than 16%. The limits of detection (LODs) and quantification (LOQs) of all the investigated analytes were in the range of 0.8-2.5 ng mL(-1) and 2.4-7.5 ng mL(-1) (curves constructed in methanol) and 1.1-5.2 ng mL(-1) and 3.2-15.6 ng mL(-1) (curves constructed in the amniotic fluid), respectively. The method was validated at the following two concentration levels: 10 ng mL(-1) (2 x LOQ) and 20 ng mL(-1) (4 LOQ). The results confirm the validity of the SPE procedure and HPLC-FLD method for identification and quantification of bisphenols in amniotic fluid samples collected during an amniocentesis. The result obtained show that HPLC-FLD is a useful method for determination of bisphenol residues at nanogram per milliliter concentrations in amniotic fluid samples. Residues of five analytes (BADGE center dot 2H(2)O, BPAF, BADGE, BADGE center dot H2O center dot HCl and BADGE center dot 2HCl) were detected in amniotic fluid samples. Additionally, the harmfulness of bisphenols as potential pathogens that may cause karyotype disorders and contribute to preterm birth was estimated.
英文关键词bisphenols amniotic fluid samples fluorescence detector (FLD) solid-phase extraction (SPE) Scherzo SM-C18 amniocentesis
类型Article
语种英语
开放获取类型Green Published, gold
收录类别SCI-E ; SSCI
WOS记录号WOS:000762320200001
WOS关键词UNITED-STATES ; BREAST-MILK ; URINE ; SERUM
WOS类目Environmental Sciences ; Public, Environmental & Occupational Health
WOS研究方向Environmental Sciences & Ecology ; Public, Environmental & Occupational Health
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/376380
推荐引用方式
GB/T 7714
Tuzimski, Tomasz,Szubartowski, Szymon. Application of Solid-Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Eleven Bisphenols in Amniotic Fluid Samples Collected during Amniocentesis[J],2022,19(4).
APA Tuzimski, Tomasz,&Szubartowski, Szymon.(2022).Application of Solid-Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Eleven Bisphenols in Amniotic Fluid Samples Collected during Amniocentesis.INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH,19(4).
MLA Tuzimski, Tomasz,et al."Application of Solid-Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Eleven Bisphenols in Amniotic Fluid Samples Collected during Amniocentesis".INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 19.4(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Tuzimski, Tomasz]的文章
[Szubartowski, Szymon]的文章
百度学术
百度学术中相似的文章
[Tuzimski, Tomasz]的文章
[Szubartowski, Szymon]的文章
必应学术
必应学术中相似的文章
[Tuzimski, Tomasz]的文章
[Szubartowski, Szymon]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。