Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate
Maytorena, V. M.; Hinojosa, J. F.
通讯作者Hinojosa, JF (corresponding author),Univ Sonora, Dept Chem Engn & Met, Blvd Rosales & Luis Encinas, Hermosillo 83000, Sonora, Mexico.
来源期刊JOURNAL OF ENERGY ENGINEERING
ISSN0733-9402
EISSN1943-7897
出版年2022
卷号148期号:2
英文摘要This work reports a numerical study of the thermal performance of a representative room coupled with a generic earth-air heat exchanger (EAHE) in a city with a desert climate. The EAHE system was designed/selected based on previous results reported in the literature. A detailed validation was made by comparing it with experimental and numerical data reported in the literature under similar climatic conditions. A study was carried out to determine the appropriate air velocity inlet of the EAHE, based on the velocity that would provide the best cooling in the room. It also helped us to select the best air inlet and outlet configuration in the cooled space. The transient cooling capacity of an EAHE system coupled with a representative room was investigated under three different cases. It was found that the most favorable case was when the entering heat flux is by one vertical wall only. In this case, the average temperature in the room was less than the comfort temperature. Also, the flow patterns, temperature fields, heat transfer coefficients, and heat fluxes are reported for the different room configurations. The studied EAHE-Room decreases the ambient temperature by 8.4 +/- 2.6 K with a maximum of 11.3 K (Roof Case), 9.6 +/- 3 K with a maximum of 12.9 K (Wall Case), and 8.2 +/- 2.4 K with a maximum of 11 K (Mixed Case). The average coefficient of performance (COP) is compared for the situations analyzed (COP varied between 210 and 277). It was found that the COP of the EAHE is affected by the thermal load of the ventilated room. (c) 2022 American Society of Civil Engineers.
英文关键词Earth-air heat exchanger (EAHE) Cooling potential Desert climate Thermal analysis in rooms Soil Geothermal energy
类型Article
语种英语
收录类别SCI-E
WOS记录号WOS:000755246800007
WOS关键词PERFORMANCE ; SYSTEM ; EAHE ; VENTILATION ; OPERATION ; DESIGN
WOS类目Energy & Fuels ; Engineering, Civil
WOS研究方向Energy & Fuels ; Engineering
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/376197
作者单位[Maytorena, V. M.; Hinojosa, J. F.] Univ Sonora, Dept Chem Engn & Met, Blvd Rosales & Luis Encinas, Hermosillo 83000, Sonora, Mexico
推荐引用方式
GB/T 7714
Maytorena, V. M.,Hinojosa, J. F.. Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate[J],2022,148(2).
APA Maytorena, V. M.,&Hinojosa, J. F..(2022).Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate.JOURNAL OF ENERGY ENGINEERING,148(2).
MLA Maytorena, V. M.,et al."Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate".JOURNAL OF ENERGY ENGINEERING 148.2(2022).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Maytorena, V. M.]的文章
[Hinojosa, J. F.]的文章
百度学术
百度学术中相似的文章
[Maytorena, V. M.]的文章
[Hinojosa, J. F.]的文章
必应学术
必应学术中相似的文章
[Maytorena, V. M.]的文章
[Hinojosa, J. F.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。