Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.3390/en14238044 |
Energy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates | |
Pakari, Ali; Ghani, Saud | |
通讯作者 | Pakari, A (corresponding author),Qatar Univ, Coll Engn, Dept Mech & Ind Engn, POB 2713, Doha 2713, Qatar. |
来源期刊 | ENERGIES
![]() |
EISSN | 1996-1073 |
出版年 | 2021 |
卷号 | 14期号:23 |
英文摘要 | Given the substantial energy use for space cooling in buildings, integrating energy-efficient and sustainable cooling systems into buildings has become increasingly more important. Even though the cooling potential of a near-surface earth-to-air heat exchanger (EAHE) with grass cover was demonstrated in previous studies, the energy savings and environmental benefits resulting from using the EAHE have not yet been quantified. Therefore, in this study, we quantify the energy savings resulting from using a near-surface earth-to-air heat exchanger (EAHE) with grass-covered ground as a precooling unit in hot desert climates. The outlet air conditions of the EAHE during 9 months of the year (March to November), where space cooling is required, are predicted using a 3D transient CFD model, which is validated against field measurements. The EAHE is fabricated from a 1 mm thick aluminum tube with a diameter of 0.15 m and a length of 21.5 m, buried 0.4 m deep. The results showed that the EAHE can cool ambient air by up to 8.5 degrees C at an air flow rate of 607 m(3)/h, corresponding to a cooling capacity of 1700 W and a COP of 17. The daily average cooling capacity of the EAHE is about 560 W for an average operation period of 15.1 h per day. When used as a precooling unit for conventional cooling systems, the highest estimated monthly energy savings is 115 kWh, and the estimated annual savings is 741 kWh. |
英文关键词 | energy savings electricity savings precooling ground cooling computational fluid dynamics (CFD) transient simulations |
类型 | Article |
语种 | 英语 |
开放获取类型 | Green Published |
收录类别 | SCI-E |
WOS记录号 | WOS:000735645900001 |
WOS关键词 | COOLING PERFORMANCE ; GROUND COVER ; VENTILATION |
WOS类目 | Energy & Fuels |
WOS研究方向 | Energy & Fuels |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/375822 |
作者单位 | [Pakari, Ali; Ghani, Saud] Qatar Univ, Coll Engn, Dept Mech & Ind Engn, POB 2713, Doha 2713, Qatar |
推荐引用方式 GB/T 7714 | Pakari, Ali,Ghani, Saud. Energy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates[J],2021,14(23). |
APA | Pakari, Ali,&Ghani, Saud.(2021).Energy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates.ENERGIES,14(23). |
MLA | Pakari, Ali,et al."Energy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates".ENERGIES 14.23(2021). |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Pakari, Ali]的文章 |
[Ghani, Saud]的文章 |
百度学术 |
百度学术中相似的文章 |
[Pakari, Ali]的文章 |
[Ghani, Saud]的文章 |
必应学术 |
必应学术中相似的文章 |
[Pakari, Ali]的文章 |
[Ghani, Saud]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。