Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jpha.2021.01.002 |
Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS | |
Wang, Jingyuan; Qi, Likai; Hou, Chenzhi; Zhang, Tingting; Chen, Mengyi; Meng, Haitao; Su, Mengxiang; Xu, Hui; Hua, Zhendong; Wang, Youmei; Di, Bin | |
通讯作者 | Di, B (corresponding author),China Pharmaceut Univ, Dept Pharm, Nanjing 210009, Peoples R China. ; Hua, ZD ; Wang, YM (corresponding author),Minist Publ Secur Peoples Republ China, Drug Control Informat & Technol Ctr, Beijing 100741, Peoples R China. |
来源期刊 | JOURNAL OF PHARMACEUTICAL ANALYSIS
![]() |
ISSN | 2095-1779 |
EISSN | 2214-0883 |
出版年 | 2021 |
卷号 | 11期号:6 |
英文摘要 | In this study, we developed a novel on-line solid phase extraction (SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites (methamphetamine, amphetamine, morphine, codeine, 6-monoacetylmorphine, benzoylecgonine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, cocaine, ketamine, norketamine, and methcathinone) and cotinine (COT) in wastewater samples. The analysis was performed by loading 2 mL of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step (5% methanol) to eliminate interference with a total run time of 13 min. The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process. Typical analytical characteristics used for method validation were sensitivity, linearity, precision, repeatability, recovery, and matrix effects. The limit of detection (LOD) and limit of quantification (LOQ) of each target were set at 0.20 ng/L and 0.50 ng/L, respectively. The linearity was between 0.5 ng/L and 250 ng/L, except for that of COT. The intra- and inter-day precisions were <10.45% and 25.64%, respectively, and the relative recovery ranged from 83.74% to 162.26%. The method was used to analyze various wastewater samples from 33 cities in China, and the results were compared with the experimental results of identical samples analyzed using off-line SPE. The difference rate was between 19.91% and -20.44%, and the error range could be considered acceptable. These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples. (C) 2021 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. |
英文关键词 | Illicit drugs and metabolites Wastewater analysis On-line solid phase extraction Ultra-high-performance liquid chromatography Mass spectrometry |
类型 | Article |
语种 | 英语 |
开放获取类型 | Green Published, gold |
收录类别 | SCI-E |
WOS记录号 | WOS:000738315700009 |
WOS关键词 | MAJOR CHINESE CITIES ; LIQUID-CHROMATOGRAPHY ; MASS-SPECTROMETRY ; SEWAGE WATER ; ABUSE ; PHARMACEUTICALS ; SAMPLES ; EPIDEMIOLOGY ; VARIABILITY ; CONSUMPTION |
WOS类目 | Pharmacology & Pharmacy |
WOS研究方向 | Pharmacology & Pharmacy |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/375653 |
作者单位 | [Wang, Jingyuan; Qi, Likai; Hou, Chenzhi; Chen, Mengyi; Su, Mengxiang; Di, Bin] China Pharmaceut Univ, Dept Pharm, Nanjing 210009, Peoples R China; [Wang, Jingyuan; Qi, Likai; Hou, Chenzhi; Zhang, Tingting; Chen, Mengyi; Su, Mengxiang; Xu, Hui; Hua, Zhendong; Wang, Youmei; Di, Bin] China Natl Narcot Control Commiss China Pharmaceu, Nanjing 210009, Peoples R China; [Zhang, Tingting; Hua, Zhendong; Wang, Youmei] Minist Publ Secur Peoples Republ China, Drug Control Informat & Technol Ctr, Beijing 100741, Peoples R China; [Zhang, Tingting; Hua, Zhendong; Wang, Youmei] Minist Publ Secur Peoples Republ China, Key Lab Drug Monitoring & Control, Beijing 100741, Peoples R China; [Meng, Haitao] Shimadzu China Co Ltd, Analyt Applicat Ctr, Analyt Instruments Div, Nanjing 210000, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Jingyuan,Qi, Likai,Hou, Chenzhi,et al. Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS[J],2021,11(6). |
APA | Wang, Jingyuan.,Qi, Likai.,Hou, Chenzhi.,Zhang, Tingting.,Chen, Mengyi.,...&Di, Bin.(2021).Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS.JOURNAL OF PHARMACEUTICAL ANALYSIS,11(6). |
MLA | Wang, Jingyuan,et al."Automatic analytical approach for the determination of 12 illicit drugs and nicotine metabolites in wastewater using on-line SPE-UHPLC-MS/MS".JOURNAL OF PHARMACEUTICAL ANALYSIS 11.6(2021). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。