英文摘要Indoor air temperatures and energy consumption of residential building is increasing at an alarming rate. The design and development of passive and hybrid roof cooling systems with effective cooling techniques play a vital role in improving the thermal performance especially in arid regions. This study investigates the energy efficiency of five laboratory models of double skin passive and hybrid roof cooling systems. A comparative study on the thermal performance of these five systems reveals a highest 14.5 degrees C (41%) and 69(o)C (79%) reduction in the room and roof surface temperature with double skinned evaporative cooling roof system with forced convection. Similarly, significant reduction in room air and roof surface temperatures are also observed with the other types of double skin passive and hybrid roof cooling systems in comparison with the reference system. The studies have conclusively proven that the double skin passive and hybrid roof cooling systems can appreciably reduce the indoor air and roof surface temperature of residential and commercial buildings.
英文关键词Air ventilated roof double skin evaporative cooling passive and hybrid cool roof energy conversion
类型Article ; Early Access
语种英语
收录类别SCI-E
WOS记录号WOS:000729709400001
WOS关键词THERMAL PERFORMANCE ; SUMMER ; BUILDINGS
WOS类目Energy & Fuels ; Engineering, Chemical ; Environmental Sciences
WOS研究方向Energy & Fuels ; Engineering ; Environmental Sciences & Ecology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/374709
作者单位[Kumar, V. Vinod; Akeel, Norie] Sohar Univ, Fac Engn, Mech & Mechatron Engn, Sohar, Oman; [Raut, Nitin] Sohar Univ, Fac Engn, Chem Engn, Sohar, Oman
推荐引用方式
GB/T 7714
Kumar, V. Vinod,Raut, Nitin,Akeel, Norie. An experimental investigation on passive and hybrid roof cooling systems with a double skin envelope[J],2021.
APA Kumar, V. Vinod,Raut, Nitin,&Akeel, Norie.(2021).An experimental investigation on passive and hybrid roof cooling systems with a double skin envelope.ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS.
MLA Kumar, V. Vinod,et al."An experimental investigation on passive and hybrid roof cooling systems with a double skin envelope".ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS (2021).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Kumar, V. Vinod]的文章
[Raut, Nitin]的文章
[Akeel, Norie]的文章
百度学术
百度学术中相似的文章
[Kumar, V. Vinod]的文章
[Raut, Nitin]的文章
[Akeel, Norie]的文章
必应学术
必应学术中相似的文章
[Kumar, V. Vinod]的文章
[Raut, Nitin]的文章
[Akeel, Norie]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。