Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.15583/jpchrom.2021.001 |
Simultaneous Quantitative Screening for Pain Medications in Serum by High-Performance Liquid Chromatography/Time-of-Flight Mass Spectrometry with Solid-Phase Dispersive Extraction | |
Saito, Koichi; Nishiyama, Rika; Ito, Rie | |
通讯作者 | Saito, K (corresponding author), Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, 2-4-41 Ebara, Tokyo 1428501, Japan. |
来源期刊 | CHROMATOGRAPHY
![]() |
ISSN | 1342-8284 |
EISSN | 1348-3315 |
出版年 | 2021 |
卷号 | 42期号:2页码:83-90 |
英文摘要 | In this study, solid-phase dispersive extraction (SPDE) was used for serum pretreatment and in the simultaneous analysis of analgesics and adjuvant analgesics (30 types in total) that are usually used as first-and second-choice treatments for pain patients, by liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS). Examination of the optimum conditions for SPDE using Oasis MCX as the solid-phase gel revealed that the recovery rates for serum samples deproteinized in advance were 49-87%, whereas the recovery rates were as high as 78-112% when deproteinization was not performed. The matrix effect was within +/- 10% regardless of the presence or absence of deproteinization, and its influence could be suppressed even if deproteinization was not performed. The results indicate that serum deproteinization was unnecessary when SPDE was used for pretreatment. In LC/TOF-MS measurement, gradient elution was carried out using core-shell type column Kinetex C18 (150 mm x 2.1 mm, 1.7 mu m) as the LC column and 50 mM ammonium acetate buffer (pH 7.8)/acetonitrile/methanol mixture as the mobile phase. The 30 drugs were well separated, and the limit of quantification was 0.25-10 ng/mL, the correlation coefficients of the calibration curves were higher than 0.998, and the average recoveries ranged from 77.7 to 112.1%. The method would be useful to screen for analgesics and adjuvant analgesics (30 types in total) in serum in the fields of forensic science and emergency medicine. |
英文关键词 | Pain medication Solid-phase dispersive extraction LC/TOF-MS Serum |
类型 | Article |
语种 | 英语 |
开放获取类型 | gold |
收录类别 | ESCI |
WOS记录号 | WOS:000718778300002 |
WOS关键词 | NEUROPATHIC PAIN ; ANTIDEPRESSANTS ; METABOLITES ; PLASMA ; DRUGS |
WOS类目 | Chemistry, Analytical |
WOS研究方向 | Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/374249 |
作者单位 | [Saito, Koichi; Nishiyama, Rika; Ito, Rie] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, 2-4-41 Ebara, Tokyo 1428501, Japan |
推荐引用方式 GB/T 7714 | Saito, Koichi,Nishiyama, Rika,Ito, Rie. Simultaneous Quantitative Screening for Pain Medications in Serum by High-Performance Liquid Chromatography/Time-of-Flight Mass Spectrometry with Solid-Phase Dispersive Extraction[J],2021,42(2):83-90. |
APA | Saito, Koichi,Nishiyama, Rika,&Ito, Rie.(2021).Simultaneous Quantitative Screening for Pain Medications in Serum by High-Performance Liquid Chromatography/Time-of-Flight Mass Spectrometry with Solid-Phase Dispersive Extraction.CHROMATOGRAPHY,42(2),83-90. |
MLA | Saito, Koichi,et al."Simultaneous Quantitative Screening for Pain Medications in Serum by High-Performance Liquid Chromatography/Time-of-Flight Mass Spectrometry with Solid-Phase Dispersive Extraction".CHROMATOGRAPHY 42.2(2021):83-90. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。