Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s00216-021-03606-y |
Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry | |
Fernandes, Sara R.; Barreiros, Luisa; Sa, Paula; Miro, Manuel; Segundo, Marcela A. | |
通讯作者 | Segundo, MA (corresponding author), Univ Porto, Fac Farm, Dept Ciencias Quim, REQUIMTE,LAQV, Rua Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal. |
来源期刊 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY
![]() |
ISSN | 1618-2642 |
EISSN | 1618-2650 |
出版年 | 2021-08 |
英文摘要 | An automatic micro-solid-phase extraction (mu SPE) method using on-line renewable sorbent beads followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established for the determination of tranexamic acid (TXA) in urine. The mu SPE method was based on the bead injection (BI) concept combined with the mesofluidic lab-on-valve (LOV) platform. All steps of the mu SPE-BI-LOV were implemented by computer programming, rendering enhanced precision on time and flow events. Several parameters, including the type of sorbent, volume and composition of the conditioning solution, washing solution, and eluent composition, were evaluated to improve the extraction efficiency. The best results were obtained with a hydrophilic-lipophilic balanced mixed-mode sorbent, decorated with sulfonic acid groups (Oasis MCX), and 99% acetonitrile-water (50:50, v/v)-1% ammonium hydroxide as eluent. Chromatographic separation was performed using a BEH amide column coupled to MS/MS detection in positive ionization mode. Good linearity was achieved (R-2 > 0.998) for TXA concentrations in urine ranging from 300 to 3000 ng mL(-1), with LOD and LOQ of 30 and 65 ng mL(-1), respectively. Dilution integrity was observed for dilution factors up to 20,000 times, providing the extension of the upper limit of quantification to 12 mg mL(-1). The method was validated according to international guidelines and successfully applied to urine samples collected during scoliosis surgery of pediatric patients treated with TXA. |
英文关键词 | Bead injection Lab-on-valve Automation Mass spectrometry Tranexamic acid Urine |
类型 | Article ; Early Access |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:000686505600001 |
WOS关键词 | LIQUID-CHROMATOGRAPHY ; SAMPLE PREPARATION ; PLASMA |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/362448 |
作者单位 | [Fernandes, Sara R.; Barreiros, Luisa; Segundo, Marcela A.] Univ Porto, Fac Farm, Dept Ciencias Quim, REQUIMTE,LAQV, Rua Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal; [Fernandes, Sara R.; Barreiros, Luisa] Inst Politecn Porto, Escola Super Saude, Rua Dr Antonio Bernardino de Almeida 400, P-4200072 Porto, Portugal; [Sa, Paula] Ctr Hosp Univ Porto, P-4099001 Porto, Portugal; [Miro, Manuel] Univ Balearic Isl, Dept Chem, FI TRACE Grp, E-07122 Palma De Mallorca, Spain |
推荐引用方式 GB/T 7714 | Fernandes, Sara R.,Barreiros, Luisa,Sa, Paula,et al. Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry[J],2021. |
APA | Fernandes, Sara R.,Barreiros, Luisa,Sa, Paula,Miro, Manuel,&Segundo, Marcela A..(2021).Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry.ANALYTICAL AND BIOANALYTICAL CHEMISTRY. |
MLA | Fernandes, Sara R.,et al."Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry".ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2021). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。