Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.7780/kjrs.2021.37.1.10 |
The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S | |
Jin, Cheonggil; Choi, Chuluong | |
通讯作者 | Choi, C (corresponding author), Pukyong Natl Univ, Coll Environm & Marine Sci & Technol, Dept Spatial Informat Engn, Busan, South Korea. |
来源期刊 | KOREAN JOURNAL OF REMOTE SENSING
![]() |
ISSN | 1225-6161 |
EISSN | 2287-9307 |
出版年 | 2021 |
卷号 | 37期号:1页码:123-137 |
英文摘要 | In this study, we performed cross calibration of KOMPSAT-3 AEISS imaging sensor with reference to normalized pixels in the Landsat 8 OLI scenes of homogenous ROI recorded by both sensors between January 2014 and December 2019 at the Libya 4 PICS. Cross calibration is using images from a stable and well-calibrated satellite sensor as references to harmonize measurements from other sensors and/or characterize other sensors. But cross calibration has two problems; RSR and temporal difference. The RSR of KOMPSAT-3 and Landsat 8 are similar at the blue and green bands. But the red and NIR bands have a large difference. So we calculate SBAF of each sensor. We compared the SBAF estimated from the TOA Radiance simulation with KOMPSAT-3 and Landsat 8, the results displayed a difference of about 2.07 similar to 2.92% and 0.96 similar to 1.21% in the VIS and NIR bands. Before SBAF, Reflectance and Radiance difference was 0.42 similar to 23.23%. Case of difference temporal, we simulated by 6S and Landsat 8 for alignment the same acquisition time. The SBAF-corrected cross calibration coefficients using KOMPSAT-3, 6S and simulated Landsat 8 compared to the initial cross calibration without correction demonstrated a percentage difference in the spectral bands of about 0.866 similar to 1.192%. KOMPSAT-3 maximum uncertainty was estimated at 3.26 similar to 3.89%; errors due to atmospheric condition minimized to less than 1% (via 6S); Maximum deviation of KOMPSAT-3 DN was less than 1%. As the result, the results affirm that SBAF and 6s simulation enhanced cross-calibration accuracy. |
英文关键词 | Cross calibration CAL/VAL Libya 4 Pseudo Invariant Calibration Site (PICS) Spectral Band Adjustment Factor (SBAF) Relative Spectral Response (RSR) KOMPSAT-3 Landsat 8 |
类型 | Article |
语种 | 英语 |
收录类别 | ESCI |
WOS记录号 | WOS:000643290600009 |
WOS关键词 | NEAR-INFRARED CHANNELS ; RADIOMETRIC CHARACTERIZATION ; VICARIOUS CALIBRATION ; ABSOLUTE CALIBRATION ; SATELLITE SENSORS ; DESERT SITES ; ETM+ |
WOS类目 | Remote Sensing |
WOS研究方向 | Remote Sensing |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/352910 |
作者单位 | [Jin, Cheonggil; Choi, Chuluong] Pukyong Natl Univ, Coll Environm & Marine Sci & Technol, Dept Spatial Informat Engn, Busan, South Korea |
推荐引用方式 GB/T 7714 | Jin, Cheonggil,Choi, Chuluong. The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S[J],2021,37(1):123-137. |
APA | Jin, Cheonggil,&Choi, Chuluong.(2021).The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S.KOREAN JOURNAL OF REMOTE SENSING,37(1),123-137. |
MLA | Jin, Cheonggil,et al."The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S".KOREAN JOURNAL OF REMOTE SENSING 37.1(2021):123-137. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Jin, Cheonggil]的文章 |
[Choi, Chuluong]的文章 |
百度学术 |
百度学术中相似的文章 |
[Jin, Cheonggil]的文章 |
[Choi, Chuluong]的文章 |
必应学术 |
必应学术中相似的文章 |
[Jin, Cheonggil]的文章 |
[Choi, Chuluong]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。