Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.12911/22998993/137360 |
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region | |
Haji, Sara; Alla, Aicha Ait; Noureddine, Slimani; Ben Haddad, Mohamed; Moukrim, Abdellatif | |
通讯作者 | Haji, S (corresponding author), Ibn Zohr Univ, Fac Sci, Lab Aquat Syst Marine & Continental Ecosyst, Agadir, Morocco. |
来源期刊 | JOURNAL OF ECOLOGICAL ENGINEERING
![]() |
ISSN | 2299-8993 |
出版年 | 2021 |
卷号 | 22期号:6页码:83-98 |
英文摘要 | In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30 degrees C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 mu S/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater. |
英文关键词 | wastewater Morocco physicochemical parameters activated sludge Aourir bacteriological param-eters treatment plants |
类型 | Article |
语种 | 英语 |
开放获取类型 | gold |
收录类别 | ESCI |
WOS记录号 | WOS:000669553200010 |
WOS关键词 | REUSE ; FILTRATION ; RESISTANCE ; BACTERIA ; SEWAGE ; LAGOON ; SOIL |
WOS类目 | Engineering, Environmental |
WOS研究方向 | Engineering |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/352884 |
作者单位 | [Haji, Sara; Alla, Aicha Ait; Noureddine, Slimani; Ben Haddad, Mohamed] Ibn Zohr Univ, Fac Sci, Lab Aquat Syst Marine & Continental Ecosyst, Agadir, Morocco; [Moukrim, Abdellatif] Abdelamalek Essadi Univ, Fac Sci, Tetouan, Morocco |
推荐引用方式 GB/T 7714 | Haji, Sara,Alla, Aicha Ait,Noureddine, Slimani,et al. Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region[J],2021,22(6):83-98. |
APA | Haji, Sara,Alla, Aicha Ait,Noureddine, Slimani,Ben Haddad, Mohamed,&Moukrim, Abdellatif.(2021).Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region.JOURNAL OF ECOLOGICAL ENGINEERING,22(6),83-98. |
MLA | Haji, Sara,et al."Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region".JOURNAL OF ECOLOGICAL ENGINEERING 22.6(2021):83-98. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。