Arid
DOI10.12911/22998993/137360
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Haji, Sara; Alla, Aicha Ait; Noureddine, Slimani; Ben Haddad, Mohamed; Moukrim, Abdellatif
通讯作者Haji, S (corresponding author), Ibn Zohr Univ, Fac Sci, Lab Aquat Syst Marine & Continental Ecosyst, Agadir, Morocco.
来源期刊JOURNAL OF ECOLOGICAL ENGINEERING
ISSN2299-8993
出版年2021
卷号22期号:6页码:83-98
英文摘要In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30 degrees C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 mu S/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
英文关键词wastewater Morocco physicochemical parameters activated sludge Aourir bacteriological param-eters treatment plants
类型Article
语种英语
开放获取类型gold
收录类别ESCI
WOS记录号WOS:000669553200010
WOS关键词REUSE ; FILTRATION ; RESISTANCE ; BACTERIA ; SEWAGE ; LAGOON ; SOIL
WOS类目Engineering, Environmental
WOS研究方向Engineering
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/352884
作者单位[Haji, Sara; Alla, Aicha Ait; Noureddine, Slimani; Ben Haddad, Mohamed] Ibn Zohr Univ, Fac Sci, Lab Aquat Syst Marine & Continental Ecosyst, Agadir, Morocco; [Moukrim, Abdellatif] Abdelamalek Essadi Univ, Fac Sci, Tetouan, Morocco
推荐引用方式
GB/T 7714
Haji, Sara,Alla, Aicha Ait,Noureddine, Slimani,et al. Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region[J],2021,22(6):83-98.
APA Haji, Sara,Alla, Aicha Ait,Noureddine, Slimani,Ben Haddad, Mohamed,&Moukrim, Abdellatif.(2021).Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region.JOURNAL OF ECOLOGICAL ENGINEERING,22(6),83-98.
MLA Haji, Sara,et al."Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region".JOURNAL OF ECOLOGICAL ENGINEERING 22.6(2021):83-98.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Haji, Sara]的文章
[Alla, Aicha Ait]的文章
[Noureddine, Slimani]的文章
百度学术
百度学术中相似的文章
[Haji, Sara]的文章
[Alla, Aicha Ait]的文章
[Noureddine, Slimani]的文章
必应学术
必应学术中相似的文章
[Haji, Sara]的文章
[Alla, Aicha Ait]的文章
[Noureddine, Slimani]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。