Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.2174/1874210602014010698 |
A Comparative Study of Surface Hardness between Two Bioceramic Materials in an Experimental Apexification Model under Wet and Dry Conditions | |
Paul, Maria Priya; Amin, Swathi; Mayya, Arun; Naik, Rajaram; Mayya, Shreemathi S. | |
通讯作者 | Mayya, A (corresponding author), AJ Inst Dent Sci, Dept Conservat Dent & Endodont, Mangalore, India. |
来源期刊 | OPEN DENTISTRY JOURNAL
![]() |
ISSN | 1874-2106 |
出版年 | 2020 |
卷号 | 14页码:698-703 |
英文摘要 | Background: The placement of a wet cotton pellet against Mineral Trioxide Aggregate (MTA) is often recommended to ensure the completion of its setting reaction. Objective: This study aimed to evaluate the setting behaviour of MTA Angelus and NeoMTA by comparing their hardness after placing them in dry and moist conditions. Methodology: A simulated open apex was created on 40 polyvinyl tubes. The apical 4 mm of the tubes was filled with the two materials, NeoMTA Plus (Avalon Biomed Inc. Bradenton, FL, USA) and MTA Angelus (Angelus, Londrina, PR, Brazil) (n=20 per group). Both groups were subdivided into two subgroups based on the dry and wet conditions (n=10 per group). A wet cotton pellet was placed above the two materials in the wet group, and the coronal segment was sealed using Type II Glass ionomer cement (GC corporation Tokyo, Japan). Gutta-percha was placed against the test materials in the dry group with the coronal segment sealed with amalgam. Samples were placed in an oasis soaked in phosphate-buffered saline for seven days in 100% humidity and at 37 degrees C. Microhardness was measured independently at 4 and 2 mm from the apex. Hardness was compared between materials and conditions, applying analysis of variance (a =.05). Results: The presence of dry or wet conditions had no significant effect on material hardness. MTA Angelus showed significantly higher hardness values compared with NeoMTA Plus. Conclusion: The moisture of the periapical environment can compensate for the absence of a wet cotton pellet and is adequate for the setting of the materials. |
英文关键词 | Apexification Microhardness Mineral trioxide aggregate Hardness Analysis of variance Wet cotton pellet |
类型 | Article |
语种 | 英语 |
开放获取类型 | Other Gold |
收录类别 | ESCI |
WOS记录号 | WOS:000612088300036 |
WOS关键词 | MINERAL TRIOXIDE AGGREGATE ; RETENTION CHARACTERISTICS ; CEMENTS ; MTA |
WOS类目 | Dentistry, Oral Surgery & Medicine |
WOS研究方向 | Dentistry, Oral Surgery & Medicine |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/352655 |
作者单位 | [Paul, Maria Priya; Amin, Swathi; Mayya, Arun; Naik, Rajaram] AJ Inst Dent Sci, Dept Conservat Dent & Endodont, Mangalore, India; [Mayya, Shreemathi S.] Manipal Acad Higher Educ, Prasanna Sch Publ Hlth, Dept Data Sci, Manipal, India |
推荐引用方式 GB/T 7714 | Paul, Maria Priya,Amin, Swathi,Mayya, Arun,et al. A Comparative Study of Surface Hardness between Two Bioceramic Materials in an Experimental Apexification Model under Wet and Dry Conditions[J],2020,14:698-703. |
APA | Paul, Maria Priya,Amin, Swathi,Mayya, Arun,Naik, Rajaram,&Mayya, Shreemathi S..(2020).A Comparative Study of Surface Hardness between Two Bioceramic Materials in an Experimental Apexification Model under Wet and Dry Conditions.OPEN DENTISTRY JOURNAL,14,698-703. |
MLA | Paul, Maria Priya,et al."A Comparative Study of Surface Hardness between Two Bioceramic Materials in an Experimental Apexification Model under Wet and Dry Conditions".OPEN DENTISTRY JOURNAL 14(2020):698-703. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。