Arid
DOI10.3788/AOS202040.1828001
Calibration Accuracy Evaluation of Visible and Near-Infrared Bands of FY-3B MERIS
He Xingwei; Han Qi; Feng Xiaohu; Kang Ning
通讯作者Han, Q (corresponding author), China Meteorol Adm, Natl Satellite Meteorol Ctr, Beijing 100081, Peoples R China.
来源期刊ACTA OPTICA SINICA
ISSN0253-2239
出版年2020
卷号40期号:18
英文摘要FY-3B medium resolution imaging spectrometer (MERIS) cannot achieve the absolute calibration for the visible and near-infrared bands. To improve the MERIS absolute calibration accuracy, the six widely used north African desert pseudo-invariant targets arc adopted herein, taking the advantage of the high-quality SeaWiFS data to construct the bidirectional reflectance distribution function(BRDF) model and then using the MODTRAN radiative transfer model and ERA-Interim absorption gas reanalysis data to construct the spectral band adjustment factor (SHAF). Lastly, five years of FY-3B MERIS data arc used for the cross-calibration. The constructed BRDF model in this study can accurately express the top of atmosphere (TOA) reflectance (rho(TOA)) over the pseudo-invariant targets, and the prediction error is basically within 3%. The TOA reflectance of MERIS can be effectively predicted through the parameterized SHAF which considers the observation geometry and absorbed gas content. Cross-calibration results show that the time series arc extremely stable and have no obvious trends, which arc consistent with the characters of TOA reflectance over pseudo-invariant targets. Compared with the operational calibration results of MERIS L1, the cross-calibration results of bands 8-12 arc lower and the bias is less than zero, whereas for bands 13-16, the results arc higher and the bias is greater than zero. Except for band 8, the biases of the other eight bands arc within -5%-5%. The monthly mean deviation of bands with a wavelength less than 600 nm arc larger, particularly the three blue bands (bands 8-10). The monthly mean relative deviations of bands 13-16 arc relatively stable, and they arc basically within -5%-5%.
英文关键词remote sensing medium resolution imaging spectrometer cross-calibration spectral band adjustment factor bidirectional reflectance distribution function
类型Article
语种中文
收录类别ESCI
WOS记录号WOS:000619237300018
WOS类目Optics
WOS研究方向Optics
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/352508
作者单位[He Xingwei; Han Qi; Feng Xiaohu; Kang Ning] China Meteorol Adm, Natl Satellite Meteorol Ctr, Beijing 100081, Peoples R China
推荐引用方式
GB/T 7714
He Xingwei,Han Qi,Feng Xiaohu,et al. Calibration Accuracy Evaluation of Visible and Near-Infrared Bands of FY-3B MERIS[J],2020,40(18).
APA He Xingwei,Han Qi,Feng Xiaohu,&Kang Ning.(2020).Calibration Accuracy Evaluation of Visible and Near-Infrared Bands of FY-3B MERIS.ACTA OPTICA SINICA,40(18).
MLA He Xingwei,et al."Calibration Accuracy Evaluation of Visible and Near-Infrared Bands of FY-3B MERIS".ACTA OPTICA SINICA 40.18(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[He Xingwei]的文章
[Han Qi]的文章
[Feng Xiaohu]的文章
百度学术
百度学术中相似的文章
[He Xingwei]的文章
[Han Qi]的文章
[Feng Xiaohu]的文章
必应学术
必应学术中相似的文章
[He Xingwei]的文章
[Han Qi]的文章
[Feng Xiaohu]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。