Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1109/TGRS.2020.3009740 |
Radiometric Cross-Calibration of GF-4/PMS Based on Radiometric Block Adjustment | |
Han, Jie; Tao, Zui; Xie, Yong; Liu, Qiyue; Huang, Youju | |
通讯作者 | Tao, Z (corresponding author), Chinese Acad Sci, Aerosp Informat Res Inst, Beijing 100101, Peoples R China. |
来源期刊 | IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING |
ISSN | 0196-2892 |
EISSN | 1558-0644 |
出版年 | 2021 |
卷号 | 59期号:6页码:4522-4534 |
英文摘要 | To obtain more abundant target information, the panchromatic and multispectral sensor (PMS) of the GaoFen-4 (GF-4) satellite utilizes five different integration times. The optimal approach for carrying out the integrated processing of absolute radiometric calibration and radiometric difference minimization of PMS images over these five integration times remains an important issue. Therefore, taking the Dunhuang radiometric calibration site (DRCS) in China as the radiometric-transfer platform and treating the Moderate-resolution Imaging Spectroradiometer (MODIS) and Landsat-8 Operational Land Imager (OLI) as the reference sensors, a new radiometric cross-calibration method of the PMS based on radiometric block adjustment (RBA) is proposed. The validation results show that the proposed method can simultaneously maintain high absolute radiometric calibration consistency with the official calibration coefficients published by the China Centre for Resources Satellite Data and Application (CRESDA) and can reduce the radiometric difference between PMS images over different integration times. In addition, the influences of the distribution of the radiometric control points (RCPs), radiometric tie points (RTPs) filter, spectral band adjustment factor (SBAF) correction, and correction of the bidirectional reflectance distribution function (BRDF) on the calibration results are discussed. The total cross-calibration uncertainty is less than 5.21%. |
英文关键词 | Calibration Satellite broadcasting MODIS Remote sensing Uncertainty Artificial satellites Cross-calibration GaoFen-4 (GF-4) radiometric block adjustment (RBA) validation and evaluation |
类型 | Article |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:000652834200003 |
WOS关键词 | ABSOLUTE CALIBRATION ; SATELLITE SENSORS ; INTER-CALIBRATION ; DESERT SITES ; ALGORITHM |
WOS类目 | Geochemistry & Geophysics ; Engineering, Electrical & Electronic ; Remote Sensing ; Imaging Science & Photographic Technology |
WOS研究方向 | Geochemistry & Geophysics ; Engineering ; Remote Sensing ; Imaging Science & Photographic Technology |
来源机构 | 南京信息工程大学 |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/350534 |
作者单位 | [Han, Jie] Xuchang Univ, Sch Urban & Environm Sci, Xuchang 461000, Peoples R China; [Tao, Zui; Liu, Qiyue] Chinese Acad Sci, Aerosp Informat Res Inst, Beijing 100101, Peoples R China; [Xie, Yong] Nanjing Univ Informat Sci & Technol, Sch Geog & Remote Sensing, Nanjing 210044, Peoples R China; [Huang, Youju] Guangxi Zhuang Autonomous Reg Inst Nat Resources, Nanning 530000, Peoples R China |
推荐引用方式 GB/T 7714 | Han, Jie,Tao, Zui,Xie, Yong,et al. Radiometric Cross-Calibration of GF-4/PMS Based on Radiometric Block Adjustment[J]. 南京信息工程大学,2021,59(6):4522-4534. |
APA | Han, Jie,Tao, Zui,Xie, Yong,Liu, Qiyue,&Huang, Youju.(2021).Radiometric Cross-Calibration of GF-4/PMS Based on Radiometric Block Adjustment.IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING,59(6),4522-4534. |
MLA | Han, Jie,et al."Radiometric Cross-Calibration of GF-4/PMS Based on Radiometric Block Adjustment".IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING 59.6(2021):4522-4534. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。