Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s12665-021-09488-8 |
Electrocoagulation for nitrate removal in groundwater of intensive agricultural region: a case study of Harran plain, Turkey | |
Karabulut, Benan Yazici; Atasoy, Ayse Dilek; Can, Orhan Taner; Yesilnacar, Mehmet Irfan | |
通讯作者 | Karabulut, BY (corresponding author), Harran Univ, Engn Fac, Dept Environm Engn, TR-63050 Sanliurfa, Turkey. |
来源期刊 | ENVIRONMENTAL EARTH SCIENCES
![]() |
ISSN | 1866-6280 |
EISSN | 1866-6299 |
出版年 | 2021 |
卷号 | 80期号:5 |
英文摘要 | This study focuses on the mechanism of Nitrate (NO3-) removal from aqueous solutions by electrocoagulation (EC) using aluminum (Al) and iron (Fe) electrodes and on the reduction of high nitrate levels in the groundwater of an arid/semi-arid region. Influence of initial pH, varying electrode material, inter-electrode distance, initial conductivity, and nitrate concentration over percentage removal of nitrate as well as energy consumption were all studied. The process was carried out by batch method at room temperature (25 degrees C). Tests were performed on a synthetic water sample prepared in the laboratory and ten samples collected from the Harran Plain region. According to the results of experimental studies, optimum experimental conditions were found to be with Al electrodes and initial pH=6, run time=210 min, current density=2.31 A/m(2), inter-electrode distance=10 mm, and conductivity=1000 mu s/cm for removal of 80.1% nitrate (initial concentration=250 mg/L). The energy consumption for experimental setup and real groundwater were 2.07 kWh/m(3) and 1.925 kWh/m(3), respectively. As the Al electrode distance was increased from 10 to 20 mm, the percentage of nitrate removal decreased from 80.1 to 62.3% because of the decrease in electrostatic attraction. It was found that Fe electrodes did not have a significant effect on nitrate removal (12.4%). The removal efficiency of Ugurlu groundwater that has the highest nitrate concentration was found to be 62.0% for Al electrode and 39.0% for Fe electrode. The Al-Al electrode combination used in the studies yielded better efficiency than the Fe-Fe electrode combination. It is thought that this method will also be applicable to regions with the same characteristics as the arid/semi-arid study region. |
英文关键词 | Electrocoagulation Nitrate removal Groundwater Harran plain |
类型 | Article |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:000624563200006 |
WOS类目 | Environmental Sciences ; Geosciences, Multidisciplinary ; Water Resources |
WOS研究方向 | Environmental Sciences & Ecology ; Geology ; Water Resources |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/350103 |
作者单位 | [Karabulut, Benan Yazici; Atasoy, Ayse Dilek; Yesilnacar, Mehmet Irfan] Harran Univ, Engn Fac, Dept Environm Engn, TR-63050 Sanliurfa, Turkey; [Can, Orhan Taner] Bursa Tech Univ, Engn & Nat Sci Fac, Dept Environm Engn, TR-16310 Bursa, Turkey |
推荐引用方式 GB/T 7714 | Karabulut, Benan Yazici,Atasoy, Ayse Dilek,Can, Orhan Taner,et al. Electrocoagulation for nitrate removal in groundwater of intensive agricultural region: a case study of Harran plain, Turkey[J],2021,80(5). |
APA | Karabulut, Benan Yazici,Atasoy, Ayse Dilek,Can, Orhan Taner,&Yesilnacar, Mehmet Irfan.(2021).Electrocoagulation for nitrate removal in groundwater of intensive agricultural region: a case study of Harran plain, Turkey.ENVIRONMENTAL EARTH SCIENCES,80(5). |
MLA | Karabulut, Benan Yazici,et al."Electrocoagulation for nitrate removal in groundwater of intensive agricultural region: a case study of Harran plain, Turkey".ENVIRONMENTAL EARTH SCIENCES 80.5(2021). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。