Arid
DOI10.1016/j.asej.2020.12.004
Thermal efficiency of PCM filled double glazing units in Egypt
Bolteya, Ahmed M.; Elsayad, Mohamed A.; Belal, Adel M.
通讯作者Bolteya, AM (corresponding author), Arab Acad Sci Technol & Maritime Transport, Cairo Campus,1 St Al Mousheer Ahmed Ismail, Sheraton, Heliopolis, Egypt.
来源期刊AIN SHAMS ENGINEERING JOURNAL
ISSN2090-4479
EISSN2090-4495
出版年2021
卷号12期号:2页码:1523-1534
英文摘要Recent research has been focusing on using various media in glazing cavities to minimize heat transfer through translucent elements of buildings. During this study, the thermal efficiency of a Phase change material (RT28HC) glazed unit was experimentally investigated compared with that filled with air in dry arid region. Then, the effect of PCM thicknesses on the thermal efficiency of double-glazing unit (DGU) was investigated using Fluent software including internal temperature, temperature time lag, total transmitted energy, and liquid fraction. The results indicated that the effect of using PCM on room temperature is high. The internal layer's peak temperature time lag in PCM-filled DGU was around 5 h than common DGU. Also, increasing the PCM thickness can effectively improve thermal performance parameters till thickness 30 mm, and more thickness can reverse the variation trend. Hence, these outcomes could contribute to the thermal regulation of highly glazed buildings in dry arid region of Egypt. (C) 2020 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Ain Shams University.
英文关键词PCM DGU PCM thicknesses Building Thermal efficiency Finite element analysis
类型Article
语种英语
开放获取类型gold
收录类别SCI-E
WOS记录号WOS:000658530300004
WOS关键词ENERGY PERFORMANCE ; THICKNESS ; WINDOWS ; GLASS
WOS类目Engineering, Multidisciplinary
WOS研究方向Engineering
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/349422
作者单位[Bolteya, Ahmed M.; Elsayad, Mohamed A.; Belal, Adel M.] Arab Acad Sci Technol & Maritime Transport, Fac Engn & Technol, Dept Construct & Bldg Engn, Sheraton, Heliopolis, Egypt
推荐引用方式
GB/T 7714
Bolteya, Ahmed M.,Elsayad, Mohamed A.,Belal, Adel M.. Thermal efficiency of PCM filled double glazing units in Egypt[J],2021,12(2):1523-1534.
APA Bolteya, Ahmed M.,Elsayad, Mohamed A.,&Belal, Adel M..(2021).Thermal efficiency of PCM filled double glazing units in Egypt.AIN SHAMS ENGINEERING JOURNAL,12(2),1523-1534.
MLA Bolteya, Ahmed M.,et al."Thermal efficiency of PCM filled double glazing units in Egypt".AIN SHAMS ENGINEERING JOURNAL 12.2(2021):1523-1534.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Bolteya, Ahmed M.]的文章
[Elsayad, Mohamed A.]的文章
[Belal, Adel M.]的文章
百度学术
百度学术中相似的文章
[Bolteya, Ahmed M.]的文章
[Elsayad, Mohamed A.]的文章
[Belal, Adel M.]的文章
必应学术
必应学术中相似的文章
[Bolteya, Ahmed M.]的文章
[Elsayad, Mohamed A.]的文章
[Belal, Adel M.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。