Knowledge Resource Center for Ecological Environment in Arid Area
Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge | |
ZHANG Min; YUAN Dongxing; HUANG Yongming; CHEN Guohe; ZHANG Zhen | |
来源期刊 | Acta Oceanologica Sinica
![]() |
ISSN | 0253-505X |
出版年 | 2010 |
卷号 | 29期号:1页码:100-107 |
英文摘要 | The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described. An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm~3) H_2SO_4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4-85.7 nM, and the LOD (3sigma) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method. |
英文关键词 | nitrite seawater on-line preconcentration sequential injection solid phase extraction |
类型 | Article |
语种 | 英语 |
收录类别 | CSCD |
WOS研究方向 | Oceanography |
CSCD记录号 | CSCD:3804497 |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/335036 |
作者单位 | ZHANG Min, Environmental Science Research Center,Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen, Fujian 361005, China.; YUAN Dongxing, Environmental Science Research Center,Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen, Fujian 361005, China.; HUANG Yongming, Environmental Science Research Center,Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen, Fujian 361005, China.; CHEN Guohe, Environmental Science Research Center,Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen, Fujian 361005, China.; ZHANG Zhen, Environmental Science Research Center,Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen, Fujian 361005, China. |
推荐引用方式 GB/T 7714 | ZHANG Min,YUAN Dongxing,HUANG Yongming,et al. Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge[J],2010,29(1):100-107. |
APA | ZHANG Min,YUAN Dongxing,HUANG Yongming,CHEN Guohe,&ZHANG Zhen.(2010).Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge.Acta Oceanologica Sinica,29(1),100-107. |
MLA | ZHANG Min,et al."Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge".Acta Oceanologica Sinica 29.1(2010):100-107. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。