英文摘要 | Building retrofitting plays a critical role in achieving sustainable development and is an efficient way to improve the indoor air quality (IAQ) of existing spaces. The IAQ in classrooms has a significant impact on the health and academic achievement of students. However, improving the IAQ of existing classrooms is challenging if minimum architectural modifications are allowed. Different natural ventilation retrofitting techniques were proposed to improve the IAQ in existing classrooms at Jordan University of Science and Technology, which is located in a hot arid region. Computer simulations were used to analyze the ventilation rate, indoor operative temperature, relative humidity, and CO2 concentration in the base Case classroom and after the implementation of the proposed retrofitting techniques. Simulation results were compared with those obtained in the base case to determine the most efficient natural ventilation retrofitting technique. The best results were obtained by using a solar chimney to assist a wind tower, which resulted in an increase in the comfort hours during the occupation time, an improvement in the average monthly ventilation rate range, a decrease in the CO2 concentration, and an improvement in the relative humidity ratio. An energy-saving of 39% would be achieved compared with the use of split unit air condition systems. Economic assessment of the proposed system using net present value indicates positive economic viability. |
英文关键词 | Civil engineering Energy Environmental science Energy conservation Energy use in building Air quality Environmental assessment Green engineering Architecture Natural ventilation Retrofit techniques Indoor air quality Indoor air temperature Energy consumption |
类型 | Article |
语种 | 英语 |
开放获取类型 | Green Published, gold |
收录类别 | SCI-E |
WOS记录号 | WOS:000584392300114 |
WOS关键词 | INDOOR AIR-QUALITY ; THERMAL COMFORT ; SOLAR CHIMNEY ; ENVIRONMENT QUALITY ; CO2 CONCENTRATIONS ; ENERGY EFFICIENCY ; PERFORMANCE ; BUILDINGS ; SCHOOLS ; HEALTH |
WOS类目 | Multidisciplinary Sciences |
WOS研究方向 | Science & Technology - Other Topics |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/334716 |
作者单位 | [Ma'bdeh, Shouib Nouh; Al-Zghoul, Amani; Alradaideh, Tamer; Bataineh, Asma; Ahmad, Saba] Jordan Univ Sci & Technol, Dept Architecture, Irbid 22110, Jordan |
推荐引用方式 GB/T 7714 | Ma'bdeh, Shouib Nouh,Al-Zghoul, Amani,Alradaideh, Tamer,et al. Simulation study for natural ventilation retrofitting techniques in educational classrooms - A case study[J],2020,6(10). |
APA | Ma'bdeh, Shouib Nouh,Al-Zghoul, Amani,Alradaideh, Tamer,Bataineh, Asma,&Ahmad, Saba.(2020).Simulation study for natural ventilation retrofitting techniques in educational classrooms - A case study.HELIYON,6(10). |
MLA | Ma'bdeh, Shouib Nouh,et al."Simulation study for natural ventilation retrofitting techniques in educational classrooms - A case study".HELIYON 6.10(2020). |
条目包含的文件 | 条目无相关文件。 |