Performance evaluation of an indirect air cooling system combined with evaporative cooling
Sibanda, Sipho; Workneh, Tilahun Seyoum
通讯作者Sibanda, S
来源期刊HELIYON
EISSN2405-8440
出版年2020
卷号6期号:1
英文摘要This study developed an indirect air-cooling combined with evaporative cooling (IAC + EC) system for temporary storage of fruit and vegetables (FV) to improve the shelf life of fresh produce under hot and humid climatic conditions. The aim of the study was to investigate the effect of IAC + EC in providing optimum storage environment of temperature and relative humidity (RH) for the tomato fruit compared to storage under ambient conditions. The IAC + EC system had a 53-m(3) storage chamber able to store 3.8 tons of tomatoes. Solar energy during the day and a battery bank facility at night powered the cooling system. The structure was constructed and assembled at Ukulinga research center in Pietermaritzburg. The performance of the IAC + EC was evaluated based on the temperature and the RH measured hourly from 05h00-22h00 daily during a period of 28 days. Temperature and RH were measured in the psychometric unit, various positions in the storage chamber and at ambient conditions. There were significant variations (P < 0.001) in temperature and RH between storage and ambient conditions. The temperature inside the storage chamber was on average 7 degrees C-16 degrees C lower while the average RH was 13%-41% higher than ambient conditions. Temperature and RH at the exhaust end of the IAC + EC storage chamber were 16.40 degrees C and 88.9% compared to 30.9 degrees C and 47.6% under ambient conditions. Such conditions can enhance the shelf life of FV of moderate respiration rates. Inside the storage chamber, temperature was 15.7 degrees C-16.4 degrees C while the RH was 89.6%-93.8% depending on location. The cooler efficiency varied from 88.04% to 95.6%. The IAC + EC system performed at the same level as evaporative cooling under dry and arid conditions. The results in this study are evidence that IAC + EC system can provide optimum storage conditions for FV as well as being a low-cost technology utilizable in hot and sub-humid to humid areas in sub-Saharan Africa.
英文关键词Agriculture Energy Food science Industrial engineering Relative humidity Temperature Tomatoes Cooling efficiency Postharvest Environment
类型Article
语种英语
开放获取类型Green Published, gold
收录类别SCI-E
WOS记录号WOS:000510380200228
WOS关键词QUALITY ; STORAGE
WOS类目Multidisciplinary Sciences
WOS研究方向Science & Technology - Other Topics
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/334209
作者单位[Sibanda, Sipho] Inst Agr Engn, Agr Res Council, Pretoria, South Africa; [Workneh, Tilahun Seyoum] Univ KwaZulu Natal, Sch Engn, Pietermaritzburg, South Africa
推荐引用方式
GB/T 7714
Sibanda, Sipho,Workneh, Tilahun Seyoum. Performance evaluation of an indirect air cooling system combined with evaporative cooling[J],2020,6(1).
APA Sibanda, Sipho,&Workneh, Tilahun Seyoum.(2020).Performance evaluation of an indirect air cooling system combined with evaporative cooling.HELIYON,6(1).
MLA Sibanda, Sipho,et al."Performance evaluation of an indirect air cooling system combined with evaporative cooling".HELIYON 6.1(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Sibanda, Sipho]的文章
[Workneh, Tilahun Seyoum]的文章
百度学术
百度学术中相似的文章
[Sibanda, Sipho]的文章
[Workneh, Tilahun Seyoum]的文章
必应学术
必应学术中相似的文章
[Sibanda, Sipho]的文章
[Workneh, Tilahun Seyoum]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。