英文摘要A simplified analytical method comprised of solid-phase extraction (SPE) and gas chromatography coupled with negative chemical ionization mass spectrometry (GC-NCI/MS) has been developed for the determination of 10 polybrominated diphenyl ethers (PBDEs) congeners in human serum. After the extraction by Oasis (R) HLB custom-made SPE cartridges, the lipids in serum were decomposed by concentrated sulfuric acid directly added on the SPE column. The solvent for protein cleanup and the SPE conditions, such as elution solvent and its volume were optimized. The recoveries of the PBDEs spiked in fetal bovine serum relative to internal standards were in the range of 78.5% - 109.7% at five spiked levels (three spiked levels for BDE-209). The intra-day relative standard deviations (RSDs) were between 0.3% and 7.4%, while the inter-day RSDs were between 1.42% and 14.1%. The limits of detection (LOD, S/N = 3) and the limits of quantification (LOQ, S/N = 10) were in the range of 0.10 - 0.27 ng/L and 0.35 -0.91 ng/L respectively for all PBDEs, except BDE-209. The LOQ (blank concentration value x 3) for BDE-209 was 7.91 ng/L. The method was verified by accurate analysis of organic contaminant standard reference materials (SRM) 1957 and 1958. The results indicated that the proposed method is sensitive, accurate, fast, simple, low solvent consumption and suitable for the determination of tri- to deca-BDE in human serum.
英文关键词solid-phase extraction (SPE) gas chromatography coupled with negative chemical ionization mass spectrometry (GC-NCl/MS) polybrominated diphenyl ethers (PBDEs) serum
类型Article
语种中文
收录类别ESCI
WOS记录号WOS:000435249100010
WOS类目Chemistry, Analytical
WOS研究方向Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/329863
作者单位[Huang Feifei; Zhao Yunfeng; Li Jiangguang; Wu Yongning] Chinese Ctr Dis Control & Prevent, Natl Inst Nutr & Food Safety, Beijing 100050, Peoples R China
推荐引用方式
GB/T 7714
Huang Feifei,Zhao Yunfeng,Li Jiangguang,et al. Determination of polybrominated diphenvl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry[J],2011,29(8):743-749.
APA Huang Feifei,Zhao Yunfeng,Li Jiangguang,&Wu Yongning.(2011).Determination of polybrominated diphenvl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry.CHINESE JOURNAL OF CHROMATOGRAPHY,29(8),743-749.
MLA Huang Feifei,et al."Determination of polybrominated diphenvl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry".CHINESE JOURNAL OF CHROMATOGRAPHY 29.8(2011):743-749.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Huang Feifei]的文章
[Zhao Yunfeng]的文章
[Li Jiangguang]的文章
百度学术
百度学术中相似的文章
[Huang Feifei]的文章
[Zhao Yunfeng]的文章
[Li Jiangguang]的文章
必应学术
必应学术中相似的文章
[Huang Feifei]的文章
[Zhao Yunfeng]的文章
[Li Jiangguang]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。