Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chemosphere.2020.126765 |
A coupled method of on-line solid phase extraction with the UHPLC- MS/MS for detection of sulfonamides antibiotics residues in aquaculture | |
Li, Tao; Wang, Ce; Xu, Zhaoan; Chakraborty, Amit | |
通讯作者 | Wang, C |
来源期刊 | CHEMOSPHERE
![]() |
ISSN | 0045-6535 |
EISSN | 1879-1298 |
出版年 | 2020 |
卷号 | 254 |
英文摘要 | The use of a variety of antibiotics in fish farming raises serious concern about the development of antibiotic resistance. Sulfonamides antibiotics (SAs), which are widely used in aquaculture and generate large eco-toxicological effects with significant mutagenicity and teratogenic consequences, are still difficult to determine in aquatic organisms. In this study, an automatic technology was developed by coupling on-line solid phase extraction system (on-line SPE) with ultra-high-performance liquid chromatography spectrometry-mass spectrometry (UHPLC-MS/MS). Particularly, using a single on-line column in the process of sample pretreatment, e.g., HLB or C18, phospholipids that potentially caused the matrix effect cannot be removed form biological sample. We applied a mixed cation exchange column (Oasis (R) MCX) connected with a hydrophilic lipophilic balance column (Oasis (R) HLB) in series in on-line SPE clean-up to remove interferences and finally obtained a clear and stable eluant. The on-line SPE working conditions and UHPLC-MS/MS parameters were optimized for their sensitivity, accuracy, decision limit, and detection capability, which were further calibrated for fish, shrimp and crab. The results showed that the limits of detection and limits of quantification ranged from 1.46 to 15.5 ng/kg, and 4.90 -51.6 ng/kg, respectively. Accuracy values covered 71.5%-102% at the three concentration levels (0.1, 0.5, 1.0 mu g/kg) for all compounds and average repeatability (relative standard deviation, RSD%) ranged from 3.47% to 14.2%. This on-line SPE coupled with UHPLC-MS/MS method is a way forward for an automatic, powerful detection technology for determination of antibiotics from complex matrix. (C) 2020 Elsevier Ltd. All rights reserved. |
英文关键词 | on-line SPE Sulfonamides antibiotics Aquatic organisms UHPLC-MS/MS |
类型 | Article |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:000538150400026 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; LIQUID-CHROMATOGRAPHY ; MULTI-RESIDUE ; SPE-LC ; TRACE LEVELS ; WASTE-WATER ; FISH ; SAMPLES ; QUANTIFICATION ; METABOLITES |
WOS类目 | Environmental Sciences |
WOS研究方向 | Environmental Sciences & Ecology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/324657 |
作者单位 | [Li, Tao; Xu, Zhaoan] Monitoring Bur Hydrol & Water Resources Taihu Bas, Wuxi, Jiangsu, Peoples R China; [Wang, Ce] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China; [Wang, Ce] Southeast Univ, Key Lab Environm Med Engn, Minist Educ, Nanjing 210096, Peoples R China; [Chakraborty, Amit] Cent Univ Rajasthan, Sch Math Stat & Computat Sci, Ajmer, India |
推荐引用方式 GB/T 7714 | Li, Tao,Wang, Ce,Xu, Zhaoan,et al. A coupled method of on-line solid phase extraction with the UHPLC- MS/MS for detection of sulfonamides antibiotics residues in aquaculture[J],2020,254. |
APA | Li, Tao,Wang, Ce,Xu, Zhaoan,&Chakraborty, Amit.(2020).A coupled method of on-line solid phase extraction with the UHPLC- MS/MS for detection of sulfonamides antibiotics residues in aquaculture.CHEMOSPHERE,254. |
MLA | Li, Tao,et al."A coupled method of on-line solid phase extraction with the UHPLC- MS/MS for detection of sulfonamides antibiotics residues in aquaculture".CHEMOSPHERE 254(2020). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。