Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.5958/2277-8934.2020.00008.9 |
ANALYSIS OF ENDOTOXIN LEVEL IN CAMEL MILK SAMPLES COLLECTED FROM VENDING OUTLETS IN SAUDI ARABIA | |
Vijayakumar, Rajendran | |
通讯作者 | Vijayakumar, Rajendran |
来源期刊 | JOURNAL OF CAMEL PRACTICE AND RESEARCH
![]() |
ISSN | 0971-6777 |
出版年 | 2020 |
卷号 | 27期号:1页码:55-60 |
英文摘要 | The present study was done to analyse the endotoxin limits of 20 camel milk samples collected from common vending outlets, i.e. desert farms, shops etc. The milk samples were divided into 4 types (raw milk, refrigerated, boiled, stored at -20 degrees C) and processed for endotoxin analysis by Limulous Amoebocyte Lysate (LAL) Gel clot method. The microbial count was examined for raw milk sample as per standard protocols. Endotoxin limits observed in the raw milk ranged from 3 to more than 1200 EU/ml. Elevated levels of endotoxin were observed in refrigerated samples. There is no significant change of endotoxin found between raw and deep freezed, boiled samples. Endotoxin value of processed milk from shops were in the range of 3 - 300 EU/mL. Among 20 samples, the total microbial count ranged from 1 to 7.39 log CFU/ml and coliform count was 0 to 3.58 log coliforms CFU/ml. The findings of this report on the endotoxin limits of camel milk showed the levels to be between 3 to 9 EU/ml. However, the samples showed high endotoxin values (>1200 EU/mL) if improerly stored. Presence of high level of microbial and endotoxin in camel milk is unsafe for human consumption. |
英文关键词 | Camel milk endotoxin limit gel clot method LAL test microbial count |
类型 | Article |
语种 | 英语 |
国家 | Saudi Arabia |
收录类别 | SCI-E |
WOS记录号 | WOS:000552743200009 |
WOS关键词 | BACTERIOLOGICAL QUALITY ; VALUE CHAIN ; DUST ; EXPOSURE ; ASTHMA ; INDOOR ; FARM |
WOS类目 | Veterinary Sciences |
WOS研究方向 | Veterinary Sciences |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/319639 |
作者单位 | Majmaah Univ, Dept Biol, Coll Sci Zulfi, Majmaah 11952, Saudi Arabia |
推荐引用方式 GB/T 7714 | Vijayakumar, Rajendran. ANALYSIS OF ENDOTOXIN LEVEL IN CAMEL MILK SAMPLES COLLECTED FROM VENDING OUTLETS IN SAUDI ARABIA[J],2020,27(1):55-60. |
APA | Vijayakumar, Rajendran.(2020).ANALYSIS OF ENDOTOXIN LEVEL IN CAMEL MILK SAMPLES COLLECTED FROM VENDING OUTLETS IN SAUDI ARABIA.JOURNAL OF CAMEL PRACTICE AND RESEARCH,27(1),55-60. |
MLA | Vijayakumar, Rajendran."ANALYSIS OF ENDOTOXIN LEVEL IN CAMEL MILK SAMPLES COLLECTED FROM VENDING OUTLETS IN SAUDI ARABIA".JOURNAL OF CAMEL PRACTICE AND RESEARCH 27.1(2020):55-60. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Vijayakumar, Rajendran]的文章 |
百度学术 |
百度学术中相似的文章 |
[Vijayakumar, Rajendran]的文章 |
必应学术 |
必应学术中相似的文章 |
[Vijayakumar, Rajendran]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。