Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1117/12.2240472 |
Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China | |
Liu, Yaokai1,2; Li, Chuanrong1; Ma, Lingling1; Wang, Ning1; Qian, Yonggang1; Tang, Lingli1 | |
通讯作者 | Ma, Lingling |
会议名称 | Conference on Sensors, Systems, and Next-Generation Satellites XX |
会议日期 | SEP 26-28, 2016 |
会议地点 | Edinburgh, SCOTLAND |
英文摘要 | GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance. |
英文关键词 | Radiometric calibration GF-2 satellite PMS2 sensor |
来源出版物 | SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XX |
ISSN | 0277-786X |
出版年 | 2016 |
卷号 | 10000 |
ISBN | 978-1-5106-0405-6 |
EISBN | 978-1-5106-0404-9 |
出版者 | SPIE-INT SOC OPTICAL ENGINEERING |
类型 | Proceedings Paper |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | CPCI-S |
WOS记录号 | WOS:000391489900029 |
WOS关键词 | LANDSAT |
WOS类目 | Engineering, Aerospace ; Optics |
WOS研究方向 | Engineering ; Optics |
资源类型 | 会议论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/305710 |
作者单位 | 1.Chinese Acad Sci, Acad Optoelect, Key Lab Quantitat Remote Sensing Informat Technol, Beijing 100094, Peoples R China; 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Liu, Yaokai,Li, Chuanrong,Ma, Lingling,et al. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China[C]:SPIE-INT SOC OPTICAL ENGINEERING,2016. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。