Arid
DOI10.1117/12.2060226
Vicarious calibration of Terra/ASTER/VNIR with desert scenes together with cross calibration
Arai, K.
通讯作者Arai, K.
会议名称Conference on Earth Observing Systems XIX
会议日期AUG 18-20, 2014
会议地点San Diego, CA
英文摘要

Fourteen and half years of vicarious calibration and cross calibration for Terra/ASTER/VNIR (Visible and Near Infrared Radiometer, one of three ASTER mission instruments onboard Terra satellite) are summarized together with an error budget analysis. As the results, it is found that Onboard Calibration (OBC) data derived Radiometric Calibration Coefficient (RCC) is situated within a range of uncertainty of vicarious calibration except the period after approximately 4000 days after launch. In other word, uncertainty of OBC RCC is overlapped with uncertainty of vicarious calibration for about 4000 days since launch. Meanwhile, cross calibration with MODIS, MISR and ETM+ supports vicarious calibration of VNIR. In other word, Cross RCC shows much consistent trend to Vicarious RCC than OBC RCC.


英文关键词Vicarious calibration Cross calibration Onboard calibration Terra satellite Solar reflection channels of mission instruments onboard satellites
来源出版物EARTH OBSERVING SYSTEMS XIX
ISSN0277-786X
出版年2014
卷号9218
EISBN978-1-62841-245-1
出版者SPIE-INT SOC OPTICAL ENGINEERING
类型Proceedings Paper
语种英语
国家Japan
收录类别CPCI-S
WOS记录号WOS:000348319500021
WOS关键词IN-FLIGHT CALIBRATION ; SENSORS ; MISSION ; LUNAR
WOS类目Remote Sensing ; Optics
WOS研究方向Remote Sensing ; Optics
资源类型会议论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/303224
作者单位(1)Saga Univ, Dept Informat Sci, Saga 8408502, Japan
推荐引用方式
GB/T 7714
Arai, K.. Vicarious calibration of Terra/ASTER/VNIR with desert scenes together with cross calibration[C]:SPIE-INT SOC OPTICAL ENGINEERING,2014.