Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.17660/ActaHortic.2008.801.49 |
Cooling and Heating of Greenhouse in Arid Area by Earth Tube Heat Exchanger | |
Sharan, G.; Jethva, K. | |
通讯作者 | Sharan, G. |
会议名称 | International Symposium on High Technology for Greenhouse System Management (Greensys 2007) |
会议日期 | OCT 04-06, 2007 |
会议地点 | Naples, ITALY |
英文摘要 | Adoption of greenhouse technology in hot and and areas in north-west India is impeded by lack of good quality water. Besides irrigation, evaporative cooling uses large amounts. Provision of natural ventilation and coupling the house to earth-tube-heat-exchanger (ETHE) is being tried as alternative measures for environmental control, specially cooling. The experimental facility, located in arid region at Kothara (phi 23 degrees 14 N, lambda 68 degrees 45 E, at 21 m a.s.l.), is a single span saw-tooth greenhouse (20 x 6 x 3.5 m) coupled in closed- loop to ETHE buried 3m deep directly below. ETHE provides 40 air changes per hour. For natural ventilation, there are three continuous (closable) vents - two along the base of long sides and one on the roof. A retractable shading cover is provided over the roof. The aim was to determine (a) the extent to which ETHE and natural ventilation meet the need for environmental control and the associated costs (b) the extent to which the yields increase and cropping season extended. ETHE was able to heat the greenhouse easily from 9 degrees C to 22-23 degrees C in half hour in the cold winter nights. Natural ventilation along with roof shading was effective for day time control till February keeping the temperature about 34 degrees C inside. Subsequently, ETHE was operated. It limited the greenhouse temperature to 36-37 degrees C with top shaded. ETHE and natural ventilation hold promise as environmental control measures. There is need to reduce installation cost of the ETHE. A more easily scalable design than the present one is also desirable. |
英文关键词 | greenhouse earth-tube-heat-exchanger natural ventilation arid area |
来源出版物 | PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEM MANAGEMENT, VOLS 1 AND 2 |
ISSN | 0567-7572 |
出版年 | 2008 |
期号 | 801 |
页码 | 457-463 |
ISBN | 978-90-6605-621-3 |
出版者 | INTERNATIONAL SOCIETY HORTICULTURAL SCIENCE |
类型 | Proceedings Paper |
语种 | 英语 |
国家 | India |
收录类别 | CPCI-S |
WOS记录号 | WOS:000263190000049 |
WOS关键词 | SIDE OPENINGS ; RATES |
WOS类目 | Horticulture |
WOS研究方向 | Agriculture |
资源类型 | 会议论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/297346 |
作者单位 | Indian Inst Management, Ctr Management Agr, Ahmadabad 380015, Gujarat, India |
推荐引用方式 GB/T 7714 | Sharan, G.,Jethva, K.. Cooling and Heating of Greenhouse in Arid Area by Earth Tube Heat Exchanger[C]:INTERNATIONAL SOCIETY HORTICULTURAL SCIENCE,2008:457-463. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Sharan, G.]的文章 |
[Jethva, K.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Sharan, G.]的文章 |
[Jethva, K.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Sharan, G.]的文章 |
[Jethva, K.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。