Arid
DOI10.1117/12.790020
The effects of the mechanical performance and alignment of the Atacama Cosmology Telescope on the sensitivity of microwave observations
Hincks, A. D.1; Ade, P. A. R.2; Allen, C.3; Amiri, M.4; Appel, J. W.1; Battistelli, E. S.4,5; Burger, B.4; Chervenak, J. A.3; Dahlen, A. J.1; Denny, S.; Devlin, M. J.6; Dicker, S. R.6; Doriese, W. B.7; Dunner, R.8; Essinger-Hileman, T.1; Fisher, R. P.1; Fowler, J. W.1; Halpern, M.4; Hargrave, P. C.2; Hasselfield, M.4; Hilton, G. C.7; Irwin, K. D.7; Jarosik, N.; Kaul, M.6; Klein, J.6; Lau, J. M.9; Limon, M.10; Lupton, R. H.11; Marriagek, T. A.11; Martocci, K. L.12; Mauskopf, P.2; Moseley, S. H.3; Netterfield, C. B.13; Niemack, M. D.1; Nolta, M. R.14; Page, L.1; Parker, L. P.1; Sederberg, A. J.1; Staggs, S. T.1; Stryzak, O. R.1; Swetz, D. S.6; Switzer, E. R.1; Thornton, R. J.6; Tucker, C.2; Wollack, E. J.3; Zhao, Y.1
通讯作者Hincks, A. D.
会议名称Conference on Millimeter and Submillimeter Detectors and Instrumentation for Astonomy IV
会议日期JUN 26-28, 2008
会议地点Marseille, FRANCE
英文摘要

The Atacama Cosmology Telescope is a six meter, off-axis Gregorian telescope for measuring the cosmic microwave background at arcminute resolutions. The Millimeter Bolometer Array Camera (MBAC) is its current science instrument. Erected in the Atacama Desert of Chile in early 2007, it saw first light with the MBAC on 22 October 2007. In this paper we review its performance after one month of observing, focusing in particular on issues surrounding the alignment of the optical system that impact the sensitivity of the experiment. We discuss the telescope motion, pointing, and susceptibility to thermal distortions. We describe the mirror alignment procedure, which has yielded surface deviations of 31 mu m rms on the primary and 10 mu m rms on the secondary. Observations of planets show that the optical performance is consistent with the telescope design parameters. Preliminary analysis measures a, solid angle of about 215 nanosteradians with a full width at half maximum of 1.44 arcminutes at 145 GHz.


英文关键词Microwave Telescopes CMB Observations
来源出版物MILLIMETER AND SUBMILLIMETER DETECTORS AND INSTRUMENTATION FOR ASTONOMY IV
ISSN0277-786X
EISSN1996-756X
出版年2008
卷号7020
ISBN978-0-8194-7230-4
出版者SPIE-INT SOC OPTICAL ENGINEERING
类型Proceedings Paper
语种英语
国家USA;Wales;Canada;Italy;Chile
收录类别CPCI-S
WOS记录号WOS:000262259800043
WOS关键词ARRAY CAMERA ; ACT
WOS类目Astronomy & Astrophysics ; Instruments & Instrumentation ; Optics
WOS研究方向Astronomy & Astrophysics ; Instruments & Instrumentation ; Optics
资源类型会议论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/297251
作者单位1.Princeton Univ, Dept Phys, Jadwin Hall, Princeton, NJ 08544 USA;
2.Cardiff Univ, Dept Phys & Astron, Cardiff CF24 3AA, S Glam, Wales;
3.NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA;
4.Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada;
5.Univ Roma La Sapienza, Dept Phys, I-00185 Rome, Italy;
6.Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA;
7.NIST, Boulder, CO 80305 USA;
8.Pontificia Univ Catolica Chile, Fac Fis, Dept Astron & Astrofis, Santiago 22, Chile;
9.Stanford Univ, Dept Phys, Stanford, CA 94305 USA;
10.Columbia Astrophys Lab, New York, NY 10027 USA;
11.Princeton Univ, Dept Astrophys Sci, Princeton, NJ 08544 USA;
12.CUNY, Dept Phys, New York, NY 10016 USA;
13.Univ Toronto, Dept Phys, Toronto, ON M5S 1A7, Canada;
14.Univ Toronto, Canadian Inst tute Theoret Astrophys, Toronto, ON M5S 3H8, Canada
推荐引用方式
GB/T 7714
Hincks, A. D.,Ade, P. A. R.,Allen, C.,et al. The effects of the mechanical performance and alignment of the Atacama Cosmology Telescope on the sensitivity of microwave observations[C]:SPIE-INT SOC OPTICAL ENGINEERING,2008.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Hincks, A. D.]的文章
[Ade, P. A. R.]的文章
[Allen, C.]的文章
百度学术
百度学术中相似的文章
[Hincks, A. D.]的文章
[Ade, P. A. R.]的文章
[Allen, C.]的文章
必应学术
必应学术中相似的文章
[Hincks, A. D.]的文章
[Ade, P. A. R.]的文章
[Allen, C.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。