Arid
DOI10.1117/12.789738
Automated SQUID tuning procedure for kilo-pixel arrays of TES bolometers on the Atacama Cosmology Telescope
Battistelli, E. S.1,2; Amiria, M.1; Burger, B.1; Devlin, M. J.3; Dicker, S. R.3; Doriese, W. B.; Dunner, R.; Fisher, R. P.; Fowler, J. W.; Halpern, M.1; Hasselfiel, M.1; Hilton, G. C.; Hincks, A. D.; Irwin, K. D.; Kaul, M.; Klein, J.; Knotek, S.1; Lau, J. M.; Limon, M.; Marriage, T. A.; Niernack, M. D.; Page, L.; Reintsema, C. D.; Staggs, S. T.; Swetz, D. S.; Switzer, E. R.; Thornton, R. J.; Zhao, Y.
通讯作者Battistelli, E. S.
会议名称Conference on Millimeter and Submillimeter Detectors and Instrumentation for Astonomy IV
会议日期JUN 26-28, 2008
会议地点Marseille, FRANCE
英文摘要

The Atacama Cosmology Telescope observes the Cosmic Microwave Background with arcminute resolution from the Atacama desert in Chile. For the first observing season one array of 32 x 32 Transition Edge Sensor (TES) bolometers was installed in the primary ACT receiver, the Millimeter Bolometer Array Camera (MBAC). In the next season, three independent arrays working at 145., 220 and 280 GHz will be installed in MBAC. The three bolometer arrays are each coupled to a. time-domain multiplexer developed at the National Institute of Standard and Technology, Boulder, which comprises three stages of superconducting quantum interference devices (SQUIDs). The arrays and multiplexers are read-out and controlled by the Multi Channel Electronics (MCE) developed at the University of British Columbia, Vancouver.


A number of experiments plan to use the MCE as read-out electronics and thus the procedure for tuning the three stage SQUID system is of general interest. Here we describe the automated array tuning procedures and algorithms we have developed. During array tuning, the SQUIDs are biased near their critical currents. SQUID feedback currents and lock points are selected to maximize linearity, dynamic range, and gain of the SQUID response curves. Our automatic array characterization optimizes the tuning of all three stages of SQUIDs by selecting over 1100 parameters per array during the first observing season and over 2100 parameters during the second observing season. We discuss the timing, performance, and reliability of this array tuning procedure as well as planned and recently implemented improvements.


英文关键词CMB observations mm and sub-mm arrays TES bolometers SQUIDs Multi-Channel Electronics array tuning
来源出版物MILLIMETER AND SUBMILLIMETER DETECTORS AND INSTRUMENTATION FOR ASTONOMY IV
ISSN0277-786X
EISSN1996-756X
出版年2008
卷号7020
ISBN978-0-8194-7230-4
出版者SPIE-INT SOC OPTICAL ENGINEERING
类型Proceedings Paper
语种英语
国家Canada;Italy;USA
收录类别CPCI-S
WOS记录号WOS:000262259800058
WOS关键词MULTIPLEXER ; SENSORS
WOS类目Astronomy & Astrophysics ; Instruments & Instrumentation ; Optics
WOS研究方向Astronomy & Astrophysics ; Instruments & Instrumentation ; Optics
资源类型会议论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/297250
作者单位1.Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada;
2.Univ Roma La Sapienza, Dept Phys, I-00185 Rome, Italy;
3.Univ Penn, Dept Phys Astron, Philadelphia, PA 19104 USA
推荐引用方式
GB/T 7714
Battistelli, E. S.,Amiria, M.,Burger, B.,et al. Automated SQUID tuning procedure for kilo-pixel arrays of TES bolometers on the Atacama Cosmology Telescope[C]:SPIE-INT SOC OPTICAL ENGINEERING,2008.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Battistelli, E. S.]的文章
[Amiria, M.]的文章
[Burger, B.]的文章
百度学术
百度学术中相似的文章
[Battistelli, E. S.]的文章
[Amiria, M.]的文章
[Burger, B.]的文章
必应学术
必应学术中相似的文章
[Battistelli, E. S.]的文章
[Amiria, M.]的文章
[Burger, B.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。