Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s00216-007-1807-9 |
Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry | |
Dirtu, Alin C.1,2; Roosens, Laurence1; Geens, Tinne1; Gheorghe, Adriana1,3; Neels, Hugo1; Covaci, Adrian1 | |
通讯作者 | Covaci, Adrian |
会议名称 | 14th European Conference on Analytical Chemistry |
会议日期 | SEP 09-14, 2007 |
会议地点 | Antwerp, BELGIUM |
英文摘要 | This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum. |
英文关键词 | bisphenol A triclosan tetrabromobisphenol A solid-phase extraction gas chromatography-mass spectrometry human serum |
来源出版物 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY |
ISSN | 1618-2642 |
出版年 | 2008 |
卷号 | 391 |
期号 | 4 |
页码 | 1175-1181 |
出版者 | SPRINGER HEIDELBERG |
类型 | Article;Proceedings Paper |
语种 | 英语 |
国家 | Belgium;Romania |
收录类别 | SCI-E ; CPCI-S |
WOS记录号 | WOS:000256088700011 |
WOS关键词 | PERFORMANCE LIQUID-CHROMATOGRAPHY ; ENDOCRINE-DISRUPTING COMPOUNDS ; POLYBROMINATED DIPHENYL ETHERS ; PERSONAL CARE PRODUCTS ; WASTE-WATER ; ENVIRONMENTAL-SAMPLES ; PHENOLIC-COMPOUNDS ; HUMAN EXPOSURE ; SEWAGE-SLUDGE ; BREAST-MILK |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 会议论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/296980 |
作者单位 | 1.Univ Antwerp, Toxicol Ctr, Dept Pharmaceut Sci, B-2610 Antwerp, Belgium; 2.Al I Cuza Univ Iassy, Dept Inorgan & Analyt Chem, Iasi 700506, Romania; 3.Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest 050663, Romania |
推荐引用方式 GB/T 7714 | Dirtu, Alin C.,Roosens, Laurence,Geens, Tinne,et al. Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry[C]:SPRINGER HEIDELBERG,2008:1175-1181. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。