Knowledge Resource Center for Ecological Environment in Arid Area
Evaluation of pupil dynamics after implantation of artisan phakic Intraocular lenses | |
Bootsma, SJ; Tahzib, NG; Eggink, FAGJ; de Brabander, J; Nuijts, RMMA | |
通讯作者 | Nuijts, RMMA |
会议名称 | 22nd Congress of the European-Society-of-Cataract-and-Refractive-Surgeons |
会议日期 | SEP 18-22, 2004 |
会议地点 | Paris, FRANCE |
英文摘要 | PURPOSE: To compare pre- and postoperative horizontal and vertical pupil diameters after horizontal Artisan phakic intraocular lens (PIOL) (Ophtec BV, Groningen, The Netherlands) implantation for correction of myopia. METHODS: The pre- and postoperative scotopic pupil diameters measured by the Colvard pupillometer (Oasis Medical, Glendora, Calif) were compared in 71 eyes after Artisan PIOL implantation (Artisan Colvard group). Analysis of pupil shape (vertical vs horizontal diameter, V/H ratio) after horizontal Artisan PIOL implantation was performed with the Procyon pupillometer (Procyon Instruments Ltd, London, United Kingdom) in 121 eyes (Artisan Procyon group) under scotopic, mesopic-low, and mesopic-high conditions and compared to an age- and refraction-matched control group of 121 eyes of refractive surgery candidates (Procyon control group). RESULTS: After horizontal Artisan PIOL implantation, the mean horizontal pupil diameter decreased from 6.23 +/- 0.70 mm preoperatively to 5.34 +/- 0 68 mm postoperatively in the Artisan Colvard group (P<.01). The mean horizontal scotopic diameter was 5.60 +/- 0.66 mm, the mesopic-low diameter was 4.94 +/- 0.71 mm, and the mesopic-high diameter was 3.98 +/- 0.54 mm for the Artisan Procyon group. The mean horizontal scotopic diameter was 6.29 +/- 0.91 mm, the mesopic-low diameter was 5.40 +/- 0.96 mm, and the mesopic-high diameter was 4.16 +/- 0.80 mm in the Procyon control group. A significant increase was noted in V/H ratio under scotopic mesopic-low, and mesopic-high conditions from 1.02, 1.02, and 1.01, respectively, in the Procyon control group to 1.17, 1.12. and 1.06, respectively, in the Artisan Procyon group (P<.01). CONCLUSIONS: Horizontal pupil size was significantly decreased after horizontal Artisan PIOL implantation and might be attributed to a mechanical restriction of the iris in the horizontal meridian. |
来源出版物 | JOURNAL OF REFRACTIVE SURGERY |
ISSN | 1081-597X |
EISSN | 1938-2391 |
出版年 | 2006 |
卷号 | 22 |
期号 | 4 |
页码 | 367-371 |
出版者 | SLACK INC |
类型 | Article;Proceedings Paper |
语种 | 英语 |
国家 | Netherlands |
收录类别 | SCI-E ; CPCI-S |
WOS记录号 | WOS:000237159300012 |
WOS关键词 | IN-SITU KERATOMILEUSIS ; HIGH MYOPIA ; INFRARED PUPILLOMETER ; REFRACTIVE SURGERY ; NIGHT-VISION ; PHOTOREFRACTIVE KERATECTOMY ; LASIK ; SIZE ; MULTICENTER ; DIAMETERS |
WOS类目 | Ophthalmology ; Surgery |
WOS研究方向 | Ophthalmology ; Surgery |
资源类型 | 会议论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/296035 |
作者单位 | (1)Univ Hosp Maastricht, Dept Ophthalmol, NL-6202 AZ Maastricht, Netherlands |
推荐引用方式 GB/T 7714 | Bootsma, SJ,Tahzib, NG,Eggink, FAGJ,et al. Evaluation of pupil dynamics after implantation of artisan phakic Intraocular lenses[C]:SLACK INC,2006:367-371. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。