Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/S0021-9673(98)00393-8 |
Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography | |
Lopez, FJ; Beltran, J; Forcada, M; Hernandez, F | |
通讯作者 | Lopez, FJ |
会议名称 | 8th Symposium on Handling of Environmental and Biological Samples in Chromatography / 26th Scientific Meeting of the Spanish-Group-of-Chromatography |
会议日期 | OCT 26-29, 1997 |
会议地点 | ALMERIA, SPAIN |
英文摘要 | The combination of manual and automated extraction procedures using low sample volumes (5-50 ml) with large-volume oncolumn injection (LVI) (200 mu l) in capillary gas chromatography with flame photometric detection (GC-FPD) has allowed the determination of 16 organophosphorus pesticides in clean water samples at the low ng l(-1) level with an important simplification in the sample preparation step. A simple and fast offline liquid-liquid microextraction procedure (2-5 ml water/1 ml methyl tert.-butyl ether) has been applied to spiked groundwater samples (containing 0.5 ng of each pesticide) with good recoveries lover 80%) and precision (better than 10%), giving detection limits between 5 and 100 ng l(-1) using 200 mu l injections in the GC-FPD system. The application of an inline automated Liquid-Liquid microextraction-LVI-GC procedure (2 ml water/2 ml methyl tert.-butyl ether: injection of 200 mu l in GC-FPD) using the autosampler ASPEC XL led to lower recoveries (>50%) as a result of the low efficiency for mixing organic and aqueous phases, although with very satisfactory coefficients of variation (lower than 78) and detection Limits between 20 and 200 ng l(-1). Manual and automated solid-phase extraction procedures using the well known C-18 cartridges and the new Oasis HLB have been applied to groundwater samples (5-50 ml) spiked with 1 ng of each pesticide. Results obtained for both the manual and the automated procedures were satisfactory (recoveries over 80%) and the limits of detection for 50 ml sample volume ranged from 1 to 6 ng l(-1). (C) 1998 Elsevier Science B.V. All rights reserved. |
英文关键词 | extraction methods water analysis environmental analysis pesticides organophosphorus compounds large-volume injection injection methods |
来源出版物 | JOURNAL OF CHROMATOGRAPHY A |
ISSN | 0021-9673 |
出版年 | 1998 |
卷号 | 823 |
期号 | 1-2 |
页码 | 25-33 |
出版者 | ELSEVIER SCIENCE BV |
类型 | Article;Proceedings Paper |
语种 | 英语 |
国家 | Spain |
收录类别 | CPCI-S ; SCI-E |
WOS记录号 | WOS:000076610900005 |
WOS关键词 | SOLID-PHASE EXTRACTION ; ON-COLUMN INJECTION ; ATOMIC-EMISSION DETECTION ; AQUEOUS SAMPLES ; WATER ; SOLVENT |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 会议论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/292320 |
作者单位 | (1)Univ Jaume 1, Expt Sci Dept, Castellon de La Plana 12080, Spain |
推荐引用方式 GB/T 7714 | Lopez, FJ,Beltran, J,Forcada, M,et al. Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography[C]:ELSEVIER SCIENCE BV,1998:25-33. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。