Structural Design Feasibility Study for the Global Climate Experiment
Lewin,K.F.; Nagy, J.
英文摘要Neon, Inc. is proposing to establish a Global Change Experiment (GCE) Facility to increase our understanding of how ecological systems differ in their vulnerability to changes in climate and other relevant global change drivers, as well as provide the mechanistic basis for forecasting ecological change in the future. The experimental design was initially envisioned to consist of two complementary components; (A) a multi-factor experiment manipulating CO{sub 2}, temperature and water availability and (B) a water balance experiment. As the design analysis and cost estimates progressed, it became clear that (1) the technical difficulties of obtaining tight temperature control and maintaining elevated atmospheric carbon dioxide levels within an enclosure were greater than had been expected and (2) the envisioned study would not fit into the expected budget envelope if this was done in a partially or completely enclosed structure. After discussions between NEON management, the GCE science team, and Keith Lewin, NEON, Inc. requested Keith Lewin to expand the scope of this design study to include open-field exposure systems. In order to develop the GCE design to the point where it can be presented within a proposal for funding, a feasibility study of climate manipulation structures must be conducted to determine design approaches and rough cost estimates, and to identify advantages and disadvantages of these approaches including the associated experimental artifacts. NEON, Inc requested this design study in order to develop concepts for the climate manipulation structures to support the NEON Global Climate Experiment. This study summarizes the design concepts considered for constructing and operating the GCE Facility and their associated construction, maintenance and operations costs. Comparisons and comments about experimental artifacts, construction challenges and operational uncertainties are provided to assist in selecting the final facility design. The overall goal of this report is to provide a cost and technological basis for selection of the appropriate GCE Facility design.
出版年2008
报告类型Technical Report
语种英语
国家美国
来源学科分类54 ENVIRONMENTAL SCIENCES ; CARBON DIOXIDE ; CLIMATIC CHANGE ; DESIGN ; TEMPERATURE CONTROL ; TEST FACILITIES ; ENVIRONMENTAL IMPACTS
URLhttp://www.osti.gov/scitech/servlets/purl/949749
资源类型科技报告
条目标识符http://119.78.100.177/qdio/handle/2XILL650/269717
推荐引用方式
GB/T 7714
Lewin,K.F.,Nagy, J.. Structural Design Feasibility Study for the Global Climate Experiment,2008.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lewin,K.F.]的文章
[Nagy, J.]的文章
百度学术
百度学术中相似的文章
[Lewin,K.F.]的文章
[Nagy, J.]的文章
必应学术
必应学术中相似的文章
[Lewin,K.F.]的文章
[Nagy, J.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。