An evaluation of the spring finger solder joints on SA1358-10 and SA2052-4 connector assemblies (MC3617,W87).
Kilgo, Alice C.; Vianco, Paul Thomas; Hlava, Paul Frank; Zender, Gary L.
英文摘要The SA1358-10 and SA2052-4 circular JT Type plug connectors are used on a number of nuclear weapons and Joint Test Assembly (JTA) systems. Prototype units were evaluated for the following specific defects associated with the 95Sn-5Sb (Sn-Sb, wt.%) solder joint used to attach the beryllium-copper (BeCu) spring fingers to the aluminum (Al) connector shell: (1) extended cracking within the fillet; (2) remelting of the solder joint during the follow-on, soldering step that attached the EMR adapter ring to the connector shell (and/or soldering the EMR shell to the adapter ring) that used the lower melting temperature 63Sn-37Pb (Sn-Pb) alloy; and (3) spalling of the Cd (Cr) layer overplating layer from the fillet surface. Several pedigrees of connectors were evaluated, which represented older fielded units as well as those assemblies that were recently constructed at Kansas City Plant. The solder joints were evaluated that were in place on connectors made with the current soldering process as well as an alternative induction soldering process for attaching the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely reflected the different extents to which the connector was mated to its counterpart assembly. In all cases, the spring finger solder joints on the SA1358-10 connectors were remelted as a result of the subsequent EMR adapter ring attachment process. Spalling of the Cd (Cr) overplating layer was also observed for these connectors, which was a consequence of the remelting activity. On the other hand, the SA2052-4 connector did not exhibit evidence of remelting of the spring finger solder joint. The Cd (Cr) layer did not show signs of spalling. These results suggested that, due to the size of the SA1358-10 connector, any of the former or current soldering processes used to attach the EMR adapter ring and/or EMR shell to the connector shell, requires a level of heat energy that will always result in the remelting of the spring finger solder joint attached with either the Sn-Ag or the Sn-Sb alloy. Lastly, it was construed that the induction soldering process, which is used to attach the EMR adapter ring onto the shell, was more likely to have caused the remelting event rather than the more localized heat source of the hand soldering iron used to attach the EMR shell to the adapter ring.
出版年2006
报告类型Technical Report
语种英语
国家美国
来源学科分类45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEFENSE ; ALUMINIUM ; CONNECTORS ; DEFECTS ; EVALUATION ; FINGERS ; HEAT SOURCES ; INDUCTION ; IRON ; KANSAS CITY PLANT ; MELTING ; NUCLEAR WEAPONS ; SOLDERING Weapon 87 ; Nuclear weapons. ; Solder and soldering.
URLhttp://www.osti.gov/scitech/servlets/purl/889947
资源类型科技报告
条目标识符http://119.78.100.177/qdio/handle/2XILL650/269225
推荐引用方式
GB/T 7714
Kilgo, Alice C.,Vianco, Paul Thomas,Hlava, Paul Frank,et al. An evaluation of the spring finger solder joints on SA1358-10 and SA2052-4 connector assemblies (MC3617,W87).,2006.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Kilgo, Alice C.]的文章
[Vianco, Paul Thomas]的文章
[Hlava, Paul Frank]的文章
百度学术
百度学术中相似的文章
[Kilgo, Alice C.]的文章
[Vianco, Paul Thomas]的文章
[Hlava, Paul Frank]的文章
必应学术
必应学术中相似的文章
[Kilgo, Alice C.]的文章
[Vianco, Paul Thomas]的文章
[Hlava, Paul Frank]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。