Investigation of residential central air conditioning load shapes in NEMS
Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie
英文摘要This memo explains what Berkeley Lab has learned about how the residential central air-conditioning (CAC) end use is represented in the National Energy Modeling System (NEMS). NEMS is an energy model maintained by the Energy Information Administration (EIA) that is routinely used in analysis of energy efficiency standards for residential appliances. As part of analyzing utility and environmental impacts related to the federal rulemaking for residential CAC, lower-than-expected peak utility results prompted Berkeley Lab to investigate the input load shapes that characterize the peaky CAC end use and the submodule that treats load demand response. Investigations enabled a through understanding of the methodology by which hourly load profiles are input to the model and how the model is structured to respond to peak demand. Notably, it was discovered that NEMS was using an October-peaking load shape to represent residential space cooling, which suppressed peak effects to levels lower than expected. An apparent scaling down of the annual load within the load-demand submodule was found, another significant suppressor of the peak impacts. EIA promptly responded to Berkeley Lab's discoveries by updating numerous load shapes for the AEO2002 version of NEMS; EIA is still studying the scaling issue. As a result of this work, it was concluded that Berkeley Lab's customary end-use decrement approach was the most defensible way for Berkeley Lab to perform the recent CAC utility impact analysis. This approach was applied in conjunction with the updated AEO2002 load shapes to perform last year's published rulemaking analysis. Berkeley Lab experimented with several alternative approaches, including modifying the CAC efficiency level, but determined that these did not sufficiently improve the robustness of the method or results to warrant their implementation. Work in this area will continue in preparation for upcoming rulemakings for the other peak coincident end uses, commercial air conditioning and distribution transformers.
出版年2002
报告类型Technical Report
语种英语
国家美国
来源学科分类29 ENERGY PLANNING, POLICY AND ECONOMY ; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION ; AIR CONDITIONING ; APPLIANCES ; DISTRIBUTION ; EFFICIENCY ; ENERGY EFFICIENCY STANDARDS ; ENERGY MODELS ; ENVIRONMENTAL IMPACTS ; IMPLEMENTATION ; SHAPE ; SIMULATION ; TRANSFORMERS ; US ENERGY INFORMATION ADMINISTRATION
URLhttp://www.osti.gov/scitech/servlets/purl/813571
资源类型科技报告
条目标识符http://119.78.100.177/qdio/handle/2XILL650/268366
推荐引用方式
GB/T 7714
Hamachi LaCommare, Kristina,Marnay, Chris,Gumerman, Etan,et al. Investigation of residential central air conditioning load shapes in NEMS,2002.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Hamachi LaCommare, Kristina]的文章
[Marnay, Chris]的文章
[Gumerman, Etan]的文章
百度学术
百度学术中相似的文章
[Hamachi LaCommare, Kristina]的文章
[Marnay, Chris]的文章
[Gumerman, Etan]的文章
必应学术
必应学术中相似的文章
[Hamachi LaCommare, Kristina]的文章
[Marnay, Chris]的文章
[Gumerman, Etan]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。