A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions | |
Herer, C. [RRAMATOME EP/TC, Paris (France)]; Souyri, A. [EdF DER/RNE/TTA, Chatou (France)]; Garnier, J. [CEA DRN/DTP/STR/LETC, Grenoble (France)] | |
英文摘要 | Critical Heat Flux (CHF) tests were carried out in three tubes with inside diameters of 8, 13, and 19.2 mm and in two annuli with an inner tube of 9.5 mm and an outer tube of 13 or 19.2 mm. All axial heat flux distributions in the test sections were uniform. The coolant fluid was Refrigerant 12 (Freon-12) under PWR thermal-hydraulic conditions (equivalent water conditions - Pressure: 7 to 20 MPa, Mass Velocity: 1000 to 6000 kg/m2/s, Local Quality: -75% to +45%). The effect of tube diameter is correlated for qualities under 15%. The change from the tube to the annulus configuration is correctly taken into account by the equivalent hydraulic diameter. Useful information is also provided concerning the effect of a cold wall in an annulus. |
出版年 | 1995 |
报告类型 | Technical Report |
语种 | 英语 |
国家 | 美国 |
来源学科分类 | 21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS ; PWR TYPE REACTORS ; REACTOR COOLING SYSTEMS ; CRITICAL HEAT FLUX ; HEAT TRANSFER ; HYDRAULICS ; TESTING ; REFRIGERANTS ; TUBES ; DIMENSIONS ; EXPERIMENTAL DATA |
URL | http://www.osti.gov/scitech/servlets/purl/111416 |
资源类型 | 科技报告 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/266293 |
推荐引用方式 GB/T 7714 | Herer, C. [RRAMATOME EP/TC, Paris ,Souyri, A. [EdF DER/RNE/TTA, Chatou ,Garnier, J. [CEA DRN/DTP/STR/LETC, Grenoble . A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions,1995. |