Nevada Nuclear Waste Storage Investigations Project: thermal analysis of spent fuel disposal in vertical emplacement boreholes in a welded tuff repository
St. John, C.M.
英文摘要Two- and three-dimensional heat transfer analyses were conducted to determine temperatures in the vicinity of a waste canister and an emplacement drift. The effect of emplacement of canisters containing spent fuel in vertical boreholes was simulated for the cases of an emplacement drift either fully ventilated or sealed immediately after canister emplacement. PORFLOW and THERM3D respectively solve the two- and three-dimensional forms of the diffusion equation. In the unventilated case, the effect of radiation was approximated by defining an equivalent radiation thermal conductivity. A simple code, TEMP3D, based on the closed form solutions for constant and decaying heat sources, was also used. Calculations indicate that the temperature at the canister borehole wall will peak at about 215{sup 0}C if the drift is ventilated and about 240{sup 0}C if it is unventilated. The peak temperature occurs sooner in the ventilated case; after 3 to 4 yr versus 9 yr. For a point 1 m from the wall of the emplacement borehole, the corresponding peak temperatures are 150{sup 0}C for the ventilated case and 185{sup 0}C for the unventilated case and occur at about 5 and 17 yr. We assumed that the effect of drift ventilation would be to maintain a uniform temperature of 30{sup 0}C at the drift perimeter. If the drift is unventilated the wall rock temperature peaks some 75 to 100 yr after waste emplacement; reaching about 125{sup 0}C at the mid-height of the drift wall. Comparisons between the results of the three-dimensional analyses performed using TEMP3D and THERM3D indicated that the simpler modeling technique provided a good estimate of temperatures in the immediate vicinity of the canister for both the ventilated and unventilated cases. Comparisons of the results of two- and three-dimensional analyses performed using the PORFLOW and THERM3D codes indicated that the two-dimensional approximation is excellent, except in the immediate vicinity of the canister.
出版年1985
报告类型Technical Report
语种英语
国家美国
来源学科分类05 NUCLEAR FUELS ; 58 GEOSCIENCES ; TUFF ; HEAT TRANSFER ; TEMPERATURE DISTRIBUTION ; BOREHOLES ; EMPLACEMENT ; HIGH-LEVEL RADIOACTIVE WASTES ; RADIOACTIVE WASTE DISPOSAL ; COMPUTERIZED SIMULATION ; SPENT FUELS ; CONTAINERS ; Yucca Mountain Project
URLhttp://www.osti.gov/scitech/servlets/purl/59763
资源类型科技报告
条目标识符http://119.78.100.177/qdio/handle/2XILL650/263761
推荐引用方式
GB/T 7714
St. John, C.M.. Nevada Nuclear Waste Storage Investigations Project: thermal analysis of spent fuel disposal in vertical emplacement boreholes in a welded tuff repository,1985.