Direct efficiency measurement and analysis of residential oil-fired boiler systems: burner-boiler/furnace efficiency test project. Annual report FY 1978 | |
McDonald, R.J.; Batey, J.E.; Allen, T.W.; Hoppe, R.J. | |
英文摘要 | A laboratory study is made to measure the efficiencies of residential heating equipment. A direct measurement technique provides an accurate evaluation of the efficiency of residential heating units during full-load and part-load operation. The laboratory data is then used to determine annual fuel consumption and fuel-weighted seasonal efficiency for each heating unit based on typical operating parameters (size of residence, geographic location, and usage). The results of the study include both the evaluation of a wide range of hydronic (hot water) burner-boiler package units and the evaluation of retrofit items which are added to an existing heating system to enhance efficiency and performance. The combination of direct, accurate efficiency measurement, and calculation of annual fuel use provide a standard method for comparison of individual heating units and retrofit modifications on a common and realistic basis. This allows a cost effectiveness analysis to be performed so that direct quantitative comparisons can be made. |
出版年 | 1979 |
报告类型 | Technical Report |
语种 | 英语 |
国家 | 美国 |
来源学科分类 | 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION ; BOILERS ; ENERGY EFFICIENCY ; HEATING SYSTEMS ; RESIDENTIAL BUILDINGS ; BURNERS ; COMPARATIVE EVALUATIONS ; ENERGY CONSUMPTION ; HEATING OILS ; MEASURING METHODS ; MODIFICATIONS ; PERFORMANCE ; RETROFITTING ; SPECIFICATIONS ; BUILDINGS ; EFFICIENCY ; FUEL OILS ; FUELS ; OILS ; ORGANIC COMPOUNDS ; OTHER ORGANIC COMPOUNDS ; PETROLEUM PRODUCTS 320101* -- Energy Conservation, Consumption, & Utilization-- Residential Buildings-- (-1987) |
URL | http://www.osti.gov/scitech/servlets/purl/5263192 |
资源类型 | 科技报告 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/262508 |
推荐引用方式 GB/T 7714 | McDonald, R.J.,Batey, J.E.,Allen, T.W.,et al. Direct efficiency measurement and analysis of residential oil-fired boiler systems: burner-boiler/furnace efficiency test project. Annual report FY 1978,1979. |
条目包含的文件 | 条目无相关文件。 |