Arid
改进的QuEChERs-气相色谱质谱联用测定烟用接装纸中的邻苯二甲酸酯和多氯联苯
其他题名Simultaneous determination of phthalate esters (PAEs) and polychlorinated biphenyls in tipping paper for cigarette by gas chromatography-mass spectrometry coupled with modified QuEChERs
王颖; 边照阳; 李中皓; 杨飞; 刘珊珊; 邓惠敏; 范子彦; 唐纲岭
来源期刊分析试验室
ISSN1000-0720
出版年2019
卷号38期号:4页码:459-464
中文摘要采用改进的QuEChERs方法,结合气相色谱质谱联用,建立了烟用接装纸中18种邻苯二甲酸酯(PAEs)和7种多氯联苯(PCBs)同时测定的方法。样品先用水浸泡,再加入乙腈/正己烷/乙酸乙酯溶液(4:3:4,V/V/V)提取,加盐(4g MgSO_4和1.0 g NaCl)除水后,采用dSPE(50 mg PSA,50 mg C_(18),150 mg MgSO_4)初步净化,最后采用Oasis PRiME HLB柱二次净化,净化后溶液采用DB-5MS UI柱(30 m*0.25 mm,i.d.,0.25 mum)进行分离,内标法定量。25种成分的加标回收率在87.6%~103.7%;RSD< 8%,相关系数R~2> 0.995。本方法适用于烟用接装纸中PAEs和PCBs的同时测定,是一种高通量测试方法。
英文摘要A modified QuEChERs method combined with gas chromatography-mass spectrometry (GC-MS) for the simultaneous analysis of 18 phthalate esters (PAEs)and 7 polychlorinated biphenyls(PCBs) in tipping paper for cigarette was estabilished. Soaked by water,the mixture of acetonitrile/hexane/ethyl acetate (4:3:4, V/V/V)was employed as extraction solvent. After salting out by shaking with 4 g anhydrous magnesium sulfate and 1 g sodium chloride,the extract was vortexed with 50 mg primary secondary amine sorbent,50 mg C_(18) and 150 mg anhydrous magnesium sulfate sorbent. The furthermore clean-up was conducted with a new SPE cartridge of Oasis PRiME HLB. The extract was separated on DB-5MS UI column(30 m*0.25 mm,i.d.,0.25 mum) and quantified by internal standard method. The recoveries ranged from 87.6% to 103.7% and the correlation coefficient (R~2)was larger than 0.995,with RSD < 8%. The method is high-throughput and suitable for the simultaneous determination of PAEs and PCBs.
中文关键词邻苯二甲酸酯(PAEs) ; 多氯联苯(PCBs) ; 气相色谱-质谱联用(GC/MS) ; 烟用接装纸
英文关键词QuEChERs PRiME HLB Phthalate Esters (PAEs) Polychlorinated Biphenyls(PCBs) QuEChERs PRiME HLB Gas chromatography-mass spectrometry (GC-MS) Tipping paper for cigarette
语种中文
国家中国
收录类别CSCD
WOS类目CHEMISTRY ANALYTICAL
WOS研究方向Chemistry
CSCD记录号CSCD:6473808
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/239066
作者单位国家烟草质量监督检验中心, 郑州, 河南 450001, 中国
推荐引用方式
GB/T 7714
王颖,边照阳,李中皓,等. 改进的QuEChERs-气相色谱质谱联用测定烟用接装纸中的邻苯二甲酸酯和多氯联苯[J],2019,38(4):459-464.
APA 王颖.,边照阳.,李中皓.,杨飞.,刘珊珊.,...&唐纲岭.(2019).改进的QuEChERs-气相色谱质谱联用测定烟用接装纸中的邻苯二甲酸酯和多氯联苯.分析试验室,38(4),459-464.
MLA 王颖,et al."改进的QuEChERs-气相色谱质谱联用测定烟用接装纸中的邻苯二甲酸酯和多氯联苯".分析试验室 38.4(2019):459-464.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[王颖]的文章
[边照阳]的文章
[李中皓]的文章
百度学术
百度学术中相似的文章
[王颖]的文章
[边照阳]的文章
[李中皓]的文章
必应学术
必应学术中相似的文章
[王颖]的文章
[边照阳]的文章
[李中皓]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。