中文摘要为研究中国实验快堆(CEFR)非对称运行工况,通过快堆系统安全分析程序OASIS及堆芯子通道分析程序COBRA对CEFR单环路运行时堆内的温度以及流量进行了计算。结果表明,CEFR在单环路运行,完好环路一、二次钠泵转速为500r/min,且事故环路一次钠泵逆止阀开启时,堆芯最多开启在14%的功率水平,以确保反应堆处于安全状态。
英文摘要In order to study the unsymmetrical operating condition of China Experimental Fast Reactor(CEFR),the temperature and flow rate of CEFR operating with only single loop were calculated with the system analysis code OASIS and the sub-channel code COBRA.The results show that when CEFR is operating with only single loop while the rotating speeds of the primary sodium pump in that loop and the sodium pump in the corresponding secondary loop are both at 500r/min and the check valve of the other primary pump of the failed loop is open,the max power of the core should be set at 14%in order to ensure that the reactor is safe.
中文关键词中国实验快堆 ; 非对称运行工况 ; OASIS程序
英文关键词China Experimental Fast Reactor unsymmetrical operating condition OASIS code
语种中文
国家中国
收录类别CSCD
WOS类目NUCLEAR SCIENCE TECHNOLOGY
WOS研究方向Nuclear Science & Technology
CSCD记录号CSCD:5736193
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/235268
作者单位中国原子能科学研究院快堆研究设计所, 北京 102413, 中国
推荐引用方式
GB/T 7714
林超,冯预恒,周志伟. CEFR非对称运行工况的研究[J],2016,50(6):1021-1026.
APA 林超,冯预恒,&周志伟.(2016).CEFR非对称运行工况的研究.原子能科学技术,50(6),1021-1026.
MLA 林超,et al."CEFR非对称运行工况的研究".原子能科学技术 50.6(2016):1021-1026.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[林超]的文章
[冯预恒]的文章
[周志伟]的文章
百度学术
百度学术中相似的文章
[林超]的文章
[冯预恒]的文章
[周志伟]的文章
必应学术
必应学术中相似的文章
[林超]的文章
[冯预恒]的文章
[周志伟]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。