Knowledge Resource Center for Ecological Environment in Arid Area
通过式固相萃取-液相色谱-四极杆/静电场轨道阱高分辨质谱快速筛查鱼肉中全氟化合物及其前体物质 | |
其他题名 | Rapid Screening and Confirmation of Perfluorinated Compounds and Their Precursors in Fish Muscle by Solid Phase Extraction Purification and Liquid Chromatography Coupled with Quadrupole /Exactive Orbitrap Mass Spectrometry |
郭萌萌1; 国佼1; 吴海燕1; 谭志军1; 翟毓秀1; 王智2; 李兆新1; 李风铃1 | |
来源期刊 | 分析化学
![]() |
ISSN | 0253-3820 |
出版年 | 2016 |
卷号 | 44期号:10页码:1504-1513 |
中文摘要 | 采用通过式固相萃取技术去除样品基质中脂肪和磷脂等杂质干扰,利用液相色谱-四极杆/静电场轨道阱高分辨质谱(LC-Q Exactive Orbitrap MS)的同时定性定量功能,建立了鱼肉中18种全氟化合物(Perfluorinated compounds,PFCs)及其21种前体物质的同时分析方法。样品经90%乙腈溶液提取,Oasis PRiME HLB通过式固相萃取柱净化,C_(18)色谱柱分离,同时在液相色谱系统混合器和进样器之间串联一根延迟色谱柱,去除液相色谱系统的背景干扰;质谱数据采集使用Q Exactive高分辨质谱的Full MS /dd-MS~2监测模式,以Full MS一级质谱全扫描提取母离子精确质量数所得的色谱峰面积进行定量,以保留时间和dd-MS~2数据依赖子离子扫描所得的二级子离子质谱图进行定性确证。39种目标物的精确质量数偏差不大于3*10~(-6),浓度与母离子峰面积的线性关系良好,相关系数≥0.99,检出限为0.02~ 0.50 mug /kg。基质加标回收率在61.7%~ 122%之间,相对标准偏差(RSD)为6.9%~ 18.8%。本方法实现了18种PFCs及其21种前体物质的同时确证和测定,拓展了生物基质中全氟化合物的检测种类,而且前处理方法更为简化、部分化合物的灵敏度比文献报道方法提高约一个数量级,为全氟化合物前体物质的生物转化研究提供了高效的技术基础。 |
英文摘要 | A method was developed for the rapid screening and confirmation of 18 perfluorinated compounds (PFCs) and 21 precursors in fish muscle by solid phase extraction and liquid chromatography coupled with quadrupole /exactive orbitrap mass spectrometry (LC-Q Exactive Orbitrap MS). In this method,the sample was firstly extracted with acetonitrile-water (90∶ 10,V /V), cleaned-up by solid-phase extraction using Oasis PRiME HLB column. Then,39 target compounds were separated on a BEH C_(18) (2.1 mm*100 mm,1.7 mum) column,and the background interference caused by LC system was eliminated by a short C_(18) HPLC column located between the mixer and the auto sampler. In the process of quantification and qualification,a full MS / dd-MS~2 experiment was adopted in mass spectrometry acquisition,accompanied with the full scan MS date for quantification,as well as the date dependent MS~2 product ion spectra for qualification. The mass accuracy error was less than 3*10~(-6),and the calibration curves were linear well with correlation coefficient over 0.99. The limits of detection ranged from 0.02 to 0.50 mug /kg. The average spiked recoveries for 39 target compounds were between 61.7% and 122.0%,with relative standard derivations (RSDs) from 6.9% to 18.8%. The developed method was successfully applied to the simultaneous determination of 18 PFCs and 21 precursors in fish muscle with satisfactory results. |
中文关键词 | 全氟化合物及其前体物质 ; 鱼肉 ; 四极杆/静电场轨道阱高分辨质谱 ; 固相萃取 |
英文关键词 | Perfluorinated compounds and their precursors Fish muscle Quadrupole /exactive orbitrap mass spectrometry Solid phase extraction |
语种 | 中文 |
国家 | 中国 |
收录类别 | CSCD |
WOS类目 | CHEMISTRY ANALYTICAL |
WOS研究方向 | Chemistry |
CSCD记录号 | CSCD:5825627 |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/234164 |
作者单位 | 1.中国水产科学研究院黄海水产研究所, 农业部水产品质量安全检测与评价重点实验室, 青岛, 山东 266071, 中国; 2.青岛市产品质量检验技术研究所,青岛市产品质量监督检验研究院, 青岛, 山东 266061, 中国 |
推荐引用方式 GB/T 7714 | 郭萌萌,国佼,吴海燕,等. 通过式固相萃取-液相色谱-四极杆/静电场轨道阱高分辨质谱快速筛查鱼肉中全氟化合物及其前体物质[J],2016,44(10):1504-1513. |
APA | 郭萌萌.,国佼.,吴海燕.,谭志军.,翟毓秀.,...&李风铃.(2016).通过式固相萃取-液相色谱-四极杆/静电场轨道阱高分辨质谱快速筛查鱼肉中全氟化合物及其前体物质.分析化学,44(10),1504-1513. |
MLA | 郭萌萌,et al."通过式固相萃取-液相色谱-四极杆/静电场轨道阱高分辨质谱快速筛查鱼肉中全氟化合物及其前体物质".分析化学 44.10(2016):1504-1513. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[郭萌萌]的文章 |
[国佼]的文章 |
[吴海燕]的文章 |
百度学术 |
百度学术中相似的文章 |
[郭萌萌]的文章 |
[国佼]的文章 |
[吴海燕]的文章 |
必应学术 |
必应学术中相似的文章 |
[郭萌萌]的文章 |
[国佼]的文章 |
[吴海燕]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。