空冷凝汽器积灰干式吹扫系统现场实验研究 | |
其他题名 | A Site Simulation Test on Compressed Air Blowers for Ash Fouling of Air Cooled Condensers |
赵波; 杨善让; 张纲; 张宏宇; 张海林; 蒋静江; 刘志超; 王文忠; 洪海清; 马士全; 胡亚才 | |
来源期刊 | 中国电机工程学报
![]() |
ISSN | 0258-8013 |
出版年 | 2013 |
卷号 | 33期号:35页码:28-35 |
中文摘要 | 直冷系统以节水率达69%~84%而在燃煤电站得到广泛应用。但在风沙大的干旱地区,若清洗不及时,空冷凝汽器则因积灰而使排汽背压升高8 kPa甚或以上,机组煤耗因而升高10~15 g/(kW?h),污染排放亦随之增大,而及时清洗所需的水资源又为环境所限。对此,该文设计了一种以压缩空气代替高压除盐水的干式吹扫系统,并在某600 MW直冷机组单排翅片管空冷凝汽器上进行了两种清洗方式的比较实验。文中介绍了干式吹扫系统的构成、实验内容及结果,拟定了吹扫效果评价方法,建立了灰垢热阻与排汽背压的定量关联,并据以比较了干式吹扫与水洗在同一清洗周期内累计清洗效果。结果表明:干式吹扫年节水量为1.47 kg/m~2,累计平均背压降低1.7 kPa,机组发电煤耗降低约2.5g/(kW?h),实现了节水、节能和减排共赢。 |
英文摘要 | Direct air cooling (DAC) system has been widely applied in coal-fired power plants for its water-saving rate of 69%~84%. However, in arid regions with large sandstorm, the exhaust pressure of steam turbine will be raised by 8kPa or more because of the ash fouling of air cooled condenser (ACC). If it is not timely cleaned, the coal consumption of unit would elevate above 10~15 g/(kW?h) and the pollution emissions increases in the meantime. But the water consumption for timely cleaning is restricted by environmental conditions. To solve the incompatible contradiction, a novel compressed air blower (CAB) system was designed to clean the ash fouling for ACC in this paper, that is, the compressed air will entirely replace desalted water as cleaning medium for the new system. The main body of this paper includes the basic components of the CAB system, the content and results of a site simulation test (SST) for CAB under multi-operation conditions on an ACC of 600MW DAC unit, the blowing evaluation indexes proposed, and the quantitative correlation between the ash fouling resistance and exhaust pressure obtained by site simulation test data processing, the comparison of accumulated cleaning effects between compressed air blowing and water washing in the same cleaning period etc. The SST results of CAB system show that:the water-saving quantity per year is 1.47 kg/m~2;the accumulated average exhaust pressure of steam turbine is reduced by 1.7 kPa and the coal consumption has been reduced by 2.5 g/(kW?h) compared to water washing. That is, the CAB system can accomplish three goals at the same time:water-saving, energy-saving and emission reduction. |
中文关键词 | 空冷凝汽器 ; 干式吹扫 ; 灰垢热阻 ; 清洗周期 ; 累计平均背压 ; 发电煤耗 |
英文关键词 | air cooled condenser compressed air blower ash fouling resistance cleaning period accumulated average exhaust pressure coal consumption |
类型 | Article |
语种 | 中文 |
国家 | 中国 |
收录类别 | CSCD |
WOS类目 | Energy & Fuels |
WOS研究方向 | Energy & Fuels |
CSCD记录号 | CSCD:5018232 |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/230478 |
作者单位 | 赵波, 浙江大学热工与动力系统研究所, 杭州, 浙江 310027, 中国.; 胡亚才, 浙江大学热工与动力系统研究所, 杭州, 浙江 310027, 中国.; 杨善让, 东北电力大学, 节能与测控技术吉林省工程实验室, 吉林 132012, 中国.; 蒋静江, 东北电力大学, 节能与测控技术吉林省工程实验室, 吉林 132012, 中国.; 刘志超, 东北电力大学, 节能与测控技术吉林省工程实验室, 吉林 132012, 中国.; 马士全, 东北电力大学, 节能与测控技术吉林省工程实验室, 吉林 132012, 中国.; 张纲, 北方联合电力有限责任公司, 呼和浩特, 内蒙古 010020, 中国.; 张宏宇, 北方联合电力有限责任公司, 呼和浩特, 内蒙古 010020, 中国.; 张海林, 北方联合电力有限责任公司, 呼和浩特, 内蒙古 010020, 中国.; 王文忠, 北方联合电力有限责任公司, 呼和浩特, 内蒙古 010020, 中国.; 洪海清, 北方联合电力有限责任公司, 呼和浩特, 内蒙古 010020, 中国. |
推荐引用方式 GB/T 7714 | 赵波,杨善让,张纲,等. 空冷凝汽器积灰干式吹扫系统现场实验研究[J],2013,33(35):28-35. |
APA | 赵波.,杨善让.,张纲.,张宏宇.,张海林.,...&胡亚才.(2013).空冷凝汽器积灰干式吹扫系统现场实验研究.中国电机工程学报,33(35),28-35. |
MLA | 赵波,et al."空冷凝汽器积灰干式吹扫系统现场实验研究".中国电机工程学报 33.35(2013):28-35. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[赵波]的文章 |
[杨善让]的文章 |
[张纲]的文章 |
百度学术 |
百度学术中相似的文章 |
[赵波]的文章 |
[杨善让]的文章 |
[张纲]的文章 |
必应学术 |
必应学术中相似的文章 |
[赵波]的文章 |
[杨善让]的文章 |
[张纲]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。