中文摘要PS材料对西北干旱区土遗址具有良好的加固效果, 能够大大提高遗址土体的力学强度和抗风蚀能力. 为了探讨PS材料对土遗址土体热传导性能的影响作用, 研制可测定土遗址土体热传导率的装置..使用新疆交河故城遗址现场的扰动土制做成土样, 进行PS材料加固土样的热传导率测定试验及室内模型试验. 结果表明, 经PS材料加固后的土遗址土体具有热传导率减小的趋势, 并且PS材料浓度越大, 加固土体的热传导率越小. 室内模型试验发现, 当外界温度变化时, PS材料加固土体对温度变化的反应比未加固土体缓慢. 这表明经PS材料加固后的土体, 由于热传导率的降低, 阻碍土体的热传导过程, 具有能减缓温差所引起的物理风化作用, 对研究西北干旱区土遗址的加固保护具有重要的意义
英文摘要As a new type of inorganic reinforced material, potassium silicate(PS) can greatly improve the mechanical strength and the ability of anti-wind erosion of earthen ruins soil after being reinforced. Therefore, a test device for determining the thermal conductivity of ruins soil was developed. Then, soil specimens were made from the disturbed soil collected from site of Jiaohe Ruins; and then, in order to study the influence of PS on the heat transfer process of the soil, the determination test of the thermal conductivity and the laboratory model test were carried out. Test results show that the thermal conductivity of PS reinforced soil is reduced; furthermore, the larger the concentration of PS is, the smaller the thermal conductivity of soil is. In addition, it is found from the laboratory model test that when external temperature changed, the PS reinforced soil responded slower to the temperature change compared with that of the untreated soil; so, it is inferred that due to PS reduced the thermal conductivity of reinforced soil, and the heat transfer process of the soil is hindered. The finding above shows that PS reinforced soil can slow down the physical weathering caused by temperature difference; and this will have an important significance on studying the conservation of earthen ruins in Northwest China arid areas
中文关键词土力学 ; PS材料 ; 土遗址保护 ; 热传导率 ; 温度测定: 室内模型试验
英文关键词soil mechanics potassium silicate(PS) materials earthen ruins protection thermal conductivity temperature measurement laboratory model test
语种中文
国家中国
收录类别CSCD
WOS类目CONSTRUCTION BUILDING TECHNOLOGY
WOS研究方向Construction & Building Technology
CSCD记录号CSCD:4121098
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/227302
作者单位1.上海交通大学土木工程系, 上海 200240, 中国;
2.敦煌研究院保护研究所, 敦煌, 甘肃 736200, 中国
推荐引用方式
GB/T 7714
张得煊,王同瑞,王旭东,等. 经PS材料加固后遗址土体热传导性能的试验研究[J],2011,30(1):202-207.
APA 张得煊,王同瑞,王旭东,&郭青林.(2011).经PS材料加固后遗址土体热传导性能的试验研究.岩石力学与工程学报,30(1),202-207.
MLA 张得煊,et al."经PS材料加固后遗址土体热传导性能的试验研究".岩石力学与工程学报 30.1(2011):202-207.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[张得煊]的文章
[王同瑞]的文章
[王旭东]的文章
百度学术
百度学术中相似的文章
[张得煊]的文章
[王同瑞]的文章
[王旭东]的文章
必应学术
必应学术中相似的文章
[张得煊]的文章
[王同瑞]的文章
[王旭东]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。