Arid
DOI10.1002/fsn3.1158
Comparison of three different lipid removal cleanup techniques prior to the analysis of sulfonamide drug residues in porcine tissues
Wang, Jie; Hu, Qiuhui; Li, Peng; Fang, Yong; Yang, Wenjian; Ma, Ning; Pei, Fei
通讯作者Pei, Fei
来源期刊FOOD SCIENCE & NUTRITION
ISSN2048-7177
出版年2019
卷号7期号:9页码:3006-3016
英文摘要A number of 17 sulfonamides (SNs) determination in porcine tissues using two new materials including Enhanced Matrix Removal for Lipid (EMR-L) and Oasis PRiME hydrophilic-lipophilic balance (HLB), and the conventional liquid-liquid extraction with n-hexane (LLE) sample preparation methods were evaluated and compared. Samples were extracted uniformly with acidified acetonitrile and cleaned up by the three sample preparation methods, and then, analytes were further separated by ultrahigh-performance liquid chromatography (UHPLC) and detected by a triple quadrupole mass spectrometry (MS/MS) or a quadrupole-time-of-flight tandem mass spectrometry (Q-TOF/MS). The results showed that the matrix effects from the EMR-L and HLB were significantly lower than that from LLE, suggesting that these two new materials are superior to n-hexane in the precipitation of proteins and the adsorption of lipids. Moreover, the recoveries of 17 SNs were quantified by the matrix-matched calibration curve at spiked level of 5, 10, and 20 mu g/kg, and 97.0% of the results satisfied method validation requirements. The samples cleaned up by EMR-L and HLB achieved the highest average recovery in liver and kidney with high moisture content, and muscle which is high in fat, respectively. In addition, Q-TOF/MS could play a good role in aided verification based on the result of repeated validation test. In summary, either combination of approaches could be used to achieve monitoring purposes; it is still worthwhile to adopt a specific sample preparation method and MS detector for the quantification in a specific matrix.
英文关键词enhanced matrix removal for lipid hydrophilic-lipophilic balance mass spectrometry porcine tissues sulfonamides
类型Article
语种英语
国家Peoples R China
开放获取类型gold, Green Published
收录类别SCI-E
WOS记录号WOS:000480203500001
WOS关键词PERFORMANCE LIQUID-CHROMATOGRAPHY ; MULTICLASS VETERINARY DRUGS ; TANDEM MASS-SPECTROMETRY ; SAMPLE PREPARATION METHODS ; ANTIBIOTIC-RESIDUES ; PESTICIDE-RESIDUES ; TRIPLE QUADRUPOLE ; RAW-MILK ; EXTRACTION ; VALIDATION
WOS类目Food Science & Technology
WOS研究方向Food Science & Technology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/215663
作者单位Nanjing Univ Finance & Econ, Coll Food Sci & Engn, Nanjing 210023, Jiangsu, Peoples R China
推荐引用方式
GB/T 7714
Wang, Jie,Hu, Qiuhui,Li, Peng,et al. Comparison of three different lipid removal cleanup techniques prior to the analysis of sulfonamide drug residues in porcine tissues[J],2019,7(9):3006-3016.
APA Wang, Jie.,Hu, Qiuhui.,Li, Peng.,Fang, Yong.,Yang, Wenjian.,...&Pei, Fei.(2019).Comparison of three different lipid removal cleanup techniques prior to the analysis of sulfonamide drug residues in porcine tissues.FOOD SCIENCE & NUTRITION,7(9),3006-3016.
MLA Wang, Jie,et al."Comparison of three different lipid removal cleanup techniques prior to the analysis of sulfonamide drug residues in porcine tissues".FOOD SCIENCE & NUTRITION 7.9(2019):3006-3016.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang, Jie]的文章
[Hu, Qiuhui]的文章
[Li, Peng]的文章
百度学术
百度学术中相似的文章
[Wang, Jie]的文章
[Hu, Qiuhui]的文章
[Li, Peng]的文章
必应学术
必应学术中相似的文章
[Wang, Jie]的文章
[Hu, Qiuhui]的文章
[Li, Peng]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。