Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.cca.2019.01.002 |
Validation of a liquid chromatography-tandem mass spectrometry method for analyzing cannabinoids in oral fluid | |
Sobolesky, Philip M.1; Smith, Breland E.1,2; Hubbard, Jacqueline A.1; Stone, Judy1; Marcotte, Thomas D.3; Grelotti, David J.3; Grant, Igor3; Fitzgerald, Robert L.1 | |
通讯作者 | Sobolesky, Philip M. |
来源期刊 | CLINICA CHIMICA ACTA
![]() |
ISSN | 0009-8981 |
EISSN | 1873-3492 |
出版年 | 2019 |
卷号 | 491页码:30-38 |
英文摘要 | A liquid chromatography tandem mass spectrometry method was developed for quantifying ten cannabinoids in oral fluid (OF). This method utilizes OF collected by the Quantisar (TM) device and concurrently quantifies cannabinol (CBN), cannabidiol (CBD), Delta(9)-tetrahydrocannabinol (TIIC), 11-hydroxy-Delta(9)-THC (11-OH-THC), 11-nor-9-carboxy-Delta(9)-THC (THC-COOH), 11-nor-9-carboxy-Delta(9)-THC glucuronide (THC-COOH-gluc), Delta(9)-THC glucuronide (THC-gluc), cannabigerol (CBG), tetrahydrocannabiverin (THCV), and Delta(9)-tetrahydrocannabinolic acid A (THCA-A). Solid phase extraction was optimized using Oasis Prime HLB 30 mg 96-well plates. Cannabinoids were separated by liquid chromatography over a BEH C18 column and detected by a Waters TQ-S micro tandem mass spectrometer. The lower limits of quantification (LLOQ) were 0.4 ng/mL for CBN, CBD, THC, 11-OH-THC, THC-gluc, and THCV; and 1.0 ng/mL for THC-COOH, THC-COOH-gluc, CBG and THCA-A. Linear ranges extended to 2000 ng/mL for THC and 200 ng/mL for all other analytes. Inter-day analytical bias and imprecision at three levels of quality control (QC) was within +/- 15%. Mean extraction efficiencies ranged from 26.0-98.8%. Applicability of this method was tested using samples collected from individuals randomly assigned to smoke either a joint containing < 0.1%, 5.9%, or 13.4% THC content. This method was able to identify and calculate the concentration of 6 of 10 cannabinoids validated in this method. |
英文关键词 | Cannabinoid THC Oral fluid Tandem mass spectrometry |
类型 | Article |
语种 | 英语 |
国家 | USA |
开放获取类型 | Green Published |
收录类别 | SCI-E ; SSCI |
WOS记录号 | WOS:000460714900006 |
WOS关键词 | ROAD TRAFFIC CRASH ; 11-NOR-DELTA(9)-TETRAHYDROCANNABINOL-9-CARBOXYLIC ACID ; WHOLE-BLOOD ; DISPOSITION ; RISK ; PLASMA |
WOS类目 | Medical Laboratory Technology |
WOS研究方向 | Medical Laboratory Technology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/214927 |
作者单位 | 1.Univ Calif San Diego, Dept Pathol, Ctr Adv Lab Med, San Diego Hlth, San Diego, CA 92103 USA; 2.Insource Diagnost, Monrovia, CA USA; 3.Univ Calif San Diego, Dept Psychiat, Ctr Med Cannabis Res, San Diego, CA 92103 USA |
推荐引用方式 GB/T 7714 | Sobolesky, Philip M.,Smith, Breland E.,Hubbard, Jacqueline A.,et al. Validation of a liquid chromatography-tandem mass spectrometry method for analyzing cannabinoids in oral fluid[J],2019,491:30-38. |
APA | Sobolesky, Philip M..,Smith, Breland E..,Hubbard, Jacqueline A..,Stone, Judy.,Marcotte, Thomas D..,...&Fitzgerald, Robert L..(2019).Validation of a liquid chromatography-tandem mass spectrometry method for analyzing cannabinoids in oral fluid.CLINICA CHIMICA ACTA,491,30-38. |
MLA | Sobolesky, Philip M.,et al."Validation of a liquid chromatography-tandem mass spectrometry method for analyzing cannabinoids in oral fluid".CLINICA CHIMICA ACTA 491(2019):30-38. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。