Arid
DOI10.1016/j.applthermaleng.2019.03.008
Critical impact factors on the cooling performance design of natural draft dry cooling tower and relevant optimization strategies
Ge, Wenjing1; Fan, Jun2; Liu, ChuanXiao2; Li, Wendong1; Chen, Guangan1; Zhao, Yuanbin1
通讯作者Zhao, Yuanbin
来源期刊APPLIED THERMAL ENGINEERING
ISSN1359-4311
出版年2019
卷号154页码:614-627
英文摘要Because of the inherent water saving merit, natural draft dry cooling towers (NDDCTs) were widely used by power units in arid regions. The cooling performance of NDDCT plays an important role in the economic and safe running of power units. Then, the design of NDDCTs should be optimized from the design stage. Considering the following factors, such as the tower shape, the radiator arrangement, the ambient crosswind, and the mass flow ratio of circulating water to exhausting steam (m), an optimization model was put forward based on theoretical analyses. Through orthogonality analysis, two critical tower shape factors were selected, which were the ratio of the tower height to its bottom diameter and the ratio of the tower throat area to its bottom shell area. Combining the number of cooling column and m, the cooling performance of NDDCTs was optimized and relevant strategies were proposed. Meanwhile, the height of tower was optimized and the minimum construction cost of NDDCT was obtained with optimized cooling performance.
英文关键词Natural draft dry cooling tower Cooling performance Optimal design Orthogonal analysis Critical factors
类型Article
语种英语
国家Peoples R China
收录类别SCI-E
WOS记录号WOS:000469892000058
WOS关键词THERMO-FLOW CHARACTERISTICS ; CROSSWIND ; RADIATORS
WOS类目Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics
WOS研究方向Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/214282
作者单位1.Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China;
2.Shandong Agr Univ, Sch Water Conservancy & Civil Engn, Tai An 271000, Shandong, Peoples R China
推荐引用方式
GB/T 7714
Ge, Wenjing,Fan, Jun,Liu, ChuanXiao,et al. Critical impact factors on the cooling performance design of natural draft dry cooling tower and relevant optimization strategies[J],2019,154:614-627.
APA Ge, Wenjing,Fan, Jun,Liu, ChuanXiao,Li, Wendong,Chen, Guangan,&Zhao, Yuanbin.(2019).Critical impact factors on the cooling performance design of natural draft dry cooling tower and relevant optimization strategies.APPLIED THERMAL ENGINEERING,154,614-627.
MLA Ge, Wenjing,et al."Critical impact factors on the cooling performance design of natural draft dry cooling tower and relevant optimization strategies".APPLIED THERMAL ENGINEERING 154(2019):614-627.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ge, Wenjing]的文章
[Fan, Jun]的文章
[Liu, ChuanXiao]的文章
百度学术
百度学术中相似的文章
[Ge, Wenjing]的文章
[Fan, Jun]的文章
[Liu, ChuanXiao]的文章
必应学术
必应学术中相似的文章
[Ge, Wenjing]的文章
[Fan, Jun]的文章
[Liu, ChuanXiao]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。